VL_YU_MASTER relay SS SS pbVL_YU_MASTER Inverted for default on
VL_583 relay FCFS pbVL_583
VL_584 relay PMonly pbVL_584 & !VL_583
VL_582 relay VL_583 | VL_584
VLBAYER relay Seven Sisters P3 HS45611/158 pbVLBAYER
VLSBER relay Seven Sisters P3 HS45611/158 pbVLSBER
VLNBER relay Seven Sisters P3 HS45611/158 pbVLNBER
VLKSPR2 relay for HS45611/133J pbVLKSPR2 Inverted for default on
VLS1_MAN_STEP momentary pbVLS1_MAN_STEP
VLS2_MAN_STEP momentary pbVLS2_MAN_STEP
VLS3_MAN_STEP momentary pbVLS3_MAN_STEP
VLS4_MAN_STEP momentary pbVLS4_MAN_STEP
VLS6_MAN_STEP momentary pbVLS6_MAN_STEP
VLCOINC relay SYSTEM{paused}
VL_WARNING relay VLS1{566} | VLS1{586} | VLS1{9002} | VLS3{566} | VLS3{520} | VLS3{586} | VLS3{9002} | VLS2{566} | VLS2{586} | VLS2{9002} | VLS4{566} | VLS4{520} | VLS4{9002} | VLS6{520} | VLS6{9002} | VL_CHECK_ARROW
SPECIALS for ATO due to complicated track layout
CLR_SU_VL22B_TO_P4 relay HS45611/133J VL22{R} & VL16{R} & RH & SU & SV & VL13{R} & QB & QC & QD & QE & RA & RB & RC & RD & VL10{N} & VL11{N} & RE & RF & RG & VL12{N} & RJ & VL15{N} & VL17{N} & VL13{R}
CLR_SU_VL22B_TO_P5 relay HS45611/133J VL22{R} & VL16{R} & RH & SU & SV & VL13{N} & VL14{N} & VL17{R} & VLKSPR2 & TC & ( !VL22{R} | 468E )
CLR_RH_VL22B_TO_P4 relay HS45611/139C VL22{RB} & RH & RJ & SV & VL17{N} & VL16{R} & VL15{N} & RG & RF & RE & VL12{N} & RD & RC & RB & RA & QD & QE & QB & QC & VL11{N} & VL10{N}
TFTG_CLR_AND_1824RB relay Seven Sisters P5 HS45615/26B ( VL19{RB} | VL24{RB} ) & TF & TG
TGTH_CLR_AND_1824RB relay Seven Sisters P5 HS45615/29B ( VL19{RB} | VL24{RB} ) & TG & TH
VL6_1USR relay Seven Sisters P3 HS45611/150D !QU & ( VL12{R} | VL6_1USR )
VL6_3URBSR relay Seven Sisters P3 HS45611/150D ( VL6{RB} & VL13{R} & !SU ) | ( !ST & VL6_3URBSR )
455C_JR relay Seven Sisters P3 15 HS45611/151D QJ &!455C & 455D
455C_JSR relay Seven Sisters P3 Only P3 HS45611/151D 455C_JR | ( QW & QX & QY & QZ & 455C_JSR)
RD_JR relay Seven Sisters P3 15 HS45611/151D RE & !RD & QD & QE
RA_RB_RC_RD_JR relay Seven Sisters P3 60 HS45611/151D RE & !( RA & RB & RC & RD ) & QD & QE
VL1001_GR relay Seven Sisters P3 HS45613/9 VL1{R} & 453B & QA & QB & QF & ( ( QG & QH & QJ & VL10{N} ) | ( QC & QD & QE & VL11{R} & VL10{R} ) )
VL1G relay Seven Sisters P3 HS45613/9 VL1001_GR
VL1_GR relay Seven Sisters P3 HS45613/9 VL1001_GR & ( ( VL10{N} & 455A & 455B & 455C & 455D & 455E ) | ( VL10{R} & RA & RB & RC & RD & RE & VL5{R} & VL1005_PR ) )
VL1005_PR relay Seven Sisters P3 HS45611/173 ( ( VL12{N} & ( VL13{N} | VL13{R} ) ) | ( VL12{R} & VL13{N} ) ) & RF & RG
VL1_2_UE relay Seven Sisters P3 HS45613/10 ( VL1001_GR | VL1_GR ) & VL10{R}
451_CSR relay Seven Sisters P3 HS45613/50 451C & 451B & 451A & 449E & ( 451_CSR | ( 449D & 449C & 449B & 449A & 447D ) )
453_CSR relay Seven Sisters P3 HS45613/51B 453B & 453A & 451C & 451B & ( 453_CSR | ( 451A & 449E & 449D & 449C & ( !451_CSR | 449B ) ) )
VL1_CSR relay Seven Sisters P3 HS45613/52 VL1{RB} & !VL1A_SR & QA & QB & QF & ( ( QG &QH & QJ & VL10{N} ) | ( QC & QD & QE & VL10{R} ) ) & ( VL1_CSR | ( ( ( 449D & 449E ) | ( VL10{N} & !453_CSR ) ) & 451A & 451B & 451C & 453A & 453B & ( VL10{N} | ( VL10{R} & VL11{R} ) ) & VL1{R} ) )
455_CSR relay Seven Sisters P3 HS45613/53 QH & QJ & 455A & 455B & 455C & 455D & 455E & ( ( 455_CSR & ( !QF | !QG | VL1{RB} ) ) | ( VL1{R} & VL10{N} & VL1_CSR & 451B & 451C & 453A & 453B & QA & QB & QF & QG ) )
VL1_CSCR relay Seven Sisters P3 HS45613/54 !VL1_CSR & 453B & ( VL1_CSCR | ( 453A & 451C & 451B & !451A ) )
VL1A_SR relay Seven Sisters P3 HS45613/55 455C & 455D & 455E & 455A & 455B & QG & QH & QJ & ( !QF | VL1{RB} ) & ( VL1A_SR | ( VL1{R} & VL10{N} & QF & QB & QA & 453B & VL1_CSCR & !455_CSR & !453A ) )
VL1B_SR relay Seven Sisters P3 HS45613/56 455F & 455E & 455D & 455C & ( VL1B_SR | ( 455A & 455B & VL1A_SR & QG & QH & QJ & !QF ) )
VL2_CSR relay Seven Sisters P3 HS45612/31 !VL1A_SR & VL2{R} & QT & QU & 455F & 455E & 455D & 455C & ( VL2_CSR | ( 455B & 455A & QJ & QH & QG & QF & 453B & QA & QB & 455_CSR & VL12{N} ) )
VLKS3 switch Seven Sisters P3 1
VLPRKS2 switch Seven Sisters P3 HS45611/168E 1
VL1019_PR relay Seven Sisters P3 HS45611/168E VLPRKS2 & TE
VL1_L relay Seven Sisters P3 HS45611/24 453B & QA & ( ( 451A & 451B & 451C & 453A & VL1_UCLR ) | ( VL1_JNSR & VL9{R} ) | ( dQG_R & VL10{N} ) | ( dQC_R & VL10{R} ) )
VL1_JNSR relay Seven Sisters P3 HS45611/24 453B & QA & !453A & VL1{AC} & ( VL9{N} | VL1_JNSR )
VL1_UCLR relay Seven Sisters P3 HS45611/24 451A & 451B & 451C & 453A & ( VL1_UCLR | VL1{N} | ( dQC_R & VL10{R} ) | ( dQG_R & VL10{N} ) )
VL2_L relay Seven Sisters P3 HS45611/25 455D & 455E & 455F & ( 455C_JR | ( 455A & 455B & 455C & ( VL2_UCLR | ( VL2_JNSR & VL9{R} ) ) & QG & QH & QJ ) )
VL2_JNSR relay Seven Sisters P3 HS45611/25 455D & 455E & 455F & 455C & VL2{AC} & ( VL9{N} | VL2_JNSR )
VL2_UCLR relay Seven Sisters P3 HS45611/25 QG & QJ & ( VL2_UCLR | ( dQU_R & VL12{N} ) | VL2{N} )
dQU_R relay Seven Sisters P3 TBC dQU
dQC_R relay Seven Sisters P3 TBC dQC
dQG_R relay Seven Sisters P3 TBC dQG
VL4G relay Seven Sisters P3 HS45611/26C VL4{R} & VL12{N} & 455D & 455E & 455F & QT &QU & QW & QX & QY & QX
VL4_L relay Seven Sisters P3 HS45611/26C 455D & 455E & 455F & QT & ( ( 455A & 455B & 455C ) | ( VL4_JNSR & VL9{R} ) | ( dQU_R & VL12{N} ) )
VL4_JNSR relay Seven Sisters P3 HS45611/26C 455D & 455E & 455F & QT & !455C & VL4{AC} & ( VL4_JNSR | VL9{N} )
VL5_L relay Seven Sisters P3 HS45611/27 QD & QE & ( RD_JR | ( RA & RB & RC & RD & ( VL10{N} | ( ( 453A | VL1{N} ) & 453B & QA ) ) & QB ) )
VL6G relay Seven Sisters P3 HS45611/28 VL6{R} & RE & RF & RG & ( ( VL12{R} & VL13{N} & ( VL14{R} | VL15{N} ) & QT & QU & QW & QX & QY & QZ & 455D & 455E & 455F ) | ( RH & RJ & VL12{N} & ( ( VL13{N} & VL14{N} & VL15{R} & RK & RL ) | ( VL13{R} & VL15{N} & VL16{R} & VL17{N} & 464B & SP & SQ & ST & SU & SV ) ) ) )
VL6_1_UE relay Seven Sisters P3 HS45611/28 VL6G & VL12{R}
VL6_3_UE relay Seven Sisters P3 HS45611/28 VL6G & VL13{R}
VL6_ALR relay Seven Sisters P3 HS45611/29 VL6{NC} & ( VL6_ALR | ( RC & RB & RD & !VL6_LJR ) )
VL6_UCLR relay Seven Sisters P3 HS45611/30 ( ( RA & RB & RC & RD ) | VL6_ALR ) & ( VL6_UCLR | ( VL12{R} & dQU_R ) | VL6{N} )
VL6_JNSR relay Seven Sisters P3 HS45611/30 RE & RF & RG & ( ( QT & VL12{R} ) | ( RJ & ( VL13{N} | ( SU & RH & VL13{R} ) ) & VL12{N} ) ) & VL6{AC} & ( VL6_JNSR | VL9{N} )
VL6_L relay Seven Sisters P3 HS45611/30 RE & RF & RG & ( ( QT & VL12{R} ) | ( RJ & ( VL13{N} | ( SU & RH & VL13{R} ) ) & VL12{N} ) ) & ( ( VL6_JNSR | VL9{R} ) | ( VL6_ALR & ( VL6_UCLR | VL12{N} ) & VL12{R} ) | VL6_LJR )
VL6_LJR relay Seven Sisters P3 4.5 HS45611/30 RE & RF & RG & ( ( QT & VL12{R} ) | ( RJ & ( VL13{N} | ( SU & RH & VL13{R} ) ) & VL12{N} ) ) & VL6_ALR & ( VL6_UCLR | VL12{N} )
VL7_L relay Seven Sisters P3 HS45611/31B RL
VL7G relay Seven Sisters P3 HS45611/31B VL7{R} & RL & RN & RP
VL8G relay Seven Sisters P3 HS45611/32 VL8{R} & RH & RJ & RK & RL & SU & SV & TC & VL14{R} & VL15{R} & VL16{N} & VL17{R} & 468E
VL8_LJR relay Seven Sisters P3 4.5 HS45611/33 RH & RJ & SV & TC & TE & TF & TG
VL8_L relay Seven Sisters P3 HS45611/33 ( RH & RJ & SV & TC & VL8_JNSR & VL9{R} ) | VL8_LJR
VL8_JNSR relay Seven Sisters P3 HS45611/33 RH & RJ & SV & TC & ( !TG | !TF | !TE ) & VL8{AC} & ( VL9{N} | VL8_JNSR )
VL9_JCSR relay Seven Sisters P3 HS45611/34 ( VL6_JNSR | VL8_JNSR | VL20_JNSR | VL23_JNSR | VL24_JNSR | VL2_JNSR | VL4_JNSR | VL22_JNSR | VL1_JNSR ) & ( !VL9_JR | VL9_JCSR )
VL9_L relay Seven Sisters P3 HS45611/34 VL9_JCSR & VL9_JR
VL9_JR relay Seven Sisters P3 120 HS45611/34 VL9{RB}
VL10_L relay Seven Sisters P3 HS45611/35 453B & QA
VL11_L relay Seven Sisters P3 HS45611/38 QB & QC
VL12_L relay Seven Sisters P3 HS45611/40 RE & RF & QT
VL13_L relay Seven Sisters P3 HS45611/44 RG & RJ & RH & SU
VL14_L relay Seven Sisters P3 HS45611/47 RJ & RH & SV & TC
VL15_L relay Seven Sisters P3 HS45611/50 RJ
VL16_L relay Seven Sisters P3 HS45611/53 SU
VL17_L relay Seven Sisters P3 HS45611/56 TC & ( TE | TE_JR | dTG_R )
VL1018_GR relay Seven Sisters P3 HS45614/10 VL18{R} & TH & TJ & TL & TM & TN & TS & TU
VL18_GR relay Seven Sisters P3 HS45614/10 VL1018_GR & 458A & 458B & 458C & 458D
VL18G relay Seven Sisters P3 HS45614/10 VL1018_GR
VL18_L relay Seven Sisters P3 HS45611/59 TH & TJ
VL19_L relay Seven Sisters P3 HS45611/60D TC & ( !TG | ( TE & TF ) ) & SU & SV & RH & ( RJ | VL14{N} )
VL19G relay Seven Sisters P3 HS45611/60D VL19{R} & VL17{R} & TC & VL1019_PR & TF & TG & TH & TJ
VL20_LJR relay Seven Sisters P3 4.5 HS45611/61 TC & SV & RH & RJ & RK
VL20_JNSR relay Seven Sisters P3 HS45611/61 TC & SV & RH & RJ & !RK & VL20{AC} & ( VL9{N} | VL20_JNSR )
VL20G relay Seven Sisters P3 HS45611/61 VL20{R} & VL14{R} & VL15{R} & VL16{N} & VL17{R} & RH & RJ & SU & SV & TC & VL1019_PR & 468E
VL20_L relay Seven Sisters P3 HS45611/61 TC & SV & RH & RJ & ( ( RK & VL20_LJR ) | ( VL20_JNSR & VL9{R} ) )
VL21_L relay Seven Sisters P3 HS45611/62 RE & ( ( RA & RB & RC & RD ) | ( RA_RB_RC_RD_JR ) ) & QD & QE
VL22AG relay Seven Sisters P3 HS45611/64 VL22{R} & RH & SU & SV & VL16{R} & ( ( VL13{N} & VL14{N} & VL17{R} & TC & ST & VL13{N} ) | ( VL21{R} & VL12{N} & VL10{N} & VL11{N} & QB & QC & QD & QE & RA & RB & RC & RD & RE & RF & RG & VL13{R} & VL15{N} & VL17{N} & RJ & ST & !VL13{N} ) )
VL22BG relay Seven Sisters P3 HS45611/64 VL22{R} & RH & SU & SV & VL16{R} & ( ( VL13{N} & VL14{N} & VL17{R} & TC & 468E & VL1019_PR ) | ( VL21{R} & VL12{N} & VL10{N} & VL11{N} & QB & QC & QD & QE & RA & RB & RC & RD & RE & RF & RG & VL13{R} & VL15{N} & VL17{N} & RJ ) )
VL22B_2_UE relay Seven Sisters P3 HS45611/63 VL22{R} & RH & SU & SV & VL16{R} & VL21{R} & VL12{N} & VL10{N} & VL11{N} & QB & QC & QD & QE & RA & RB & RC & RD & RE & RF & RG & VL13{R} & VL15{N} & VL17{N} & RJ & VL13{R}
VL22_L relay Seven Sisters P3 HS45611/65D VL22_LJR
VL22_LJR relay Seven Sisters P3 4.5 HS45611/65D SU & ( ( SV & TC & VL13{N} ) | ( RH & RJ & RG & RE & VL13{R} ) ) & ( ( VL13{N} & dTE_R ) | ( VL13{R} & RD_JR ) | ( VL9{R} & VL22_JNSR ) | ( SP & SQ & ST ) )
VL22_JNSR relay Seven Sisters P3 HS45611/65D SU & ( ( SV & TC & VL13{N} ) | ( RH & RJ & RG & RE & VL13{R} ) ) & ( !ST | !SQ ) & VL22{AC} & ( VL9{N} | VL22_JNSR )
VL23_JNSR relay Seven Sisters P3 HS45611/66C SQ & SP & 464B & !464A & VL23{AC} & ( VL9{N} | VL23_JNSR )
VL23G relay Seven Sisters P3 HS45611/66C VL23{R} & 464B & SP & SQ & ST
VL23_L relay Seven Sisters P3 HS45611/66C 464B & SP & SQ & ( 464A | ( VL23_JNSR & VL9{R} ) )
VL1024_GR relay Seven Sisters P3 HS45615/14E VL24{R} & VL1714_PR & 468E & TE & TC & ( ( TF & TG ) | !TH )
VL24_GR relay Seven Sisters P3 HS45615/14E VL24{R} & VL1714_PR & 468E & TE & TC & TF & TG & TH & TJ
VL24G relay Seven Sisters P3 HS45615/14E VL1024_GR | VL24_GR
VL24_L relay Seven Sisters P3 HS45611/67 TC & 468E & ( ( VL24_JNSR & VL9{R} ) | ( 468B & 468C & 468D & VL24A_UCLR & VL24B_UCLR ) )
VL24_JNSR relay Seven Sisters P3 HS45611/67 TC & 468E & !468D & VL24{AC} & ( VL9{N} | VL24_JNSR )
VL24A_UCLR relay Seven Sisters P3 HS45611/68B 468C & 468D & ( VL24A_UCLR | ( dTE_R & !dTG_R & !VL24B_UCLR ) | VL24{N} )
VL24B_UCLR relay Seven Sisters P3 HS45611/68B 468C & 468D & ( VL24B_UCLR | VL24{N} | ( dTG_R & VL24A_UCLR ) )
RD_1_SPECIAL relay Seven Sisters P3 HS45611/95 !VL12{N} & ( !455D | !455E | !455F )
QW_QX_QY_QZ relay Seven Sisters P3 HS45611/95 QW & QX & QY & QZ
dS20_VL1_2 relay Seven Sisters P3 HS45613/61A 0 Fuse removed
relay Seven Sisters P3
relay Seven Sisters P3
VL24_CSR relay Seven Sisters P5 HS45615/44B TG & TH & ( ( VL24{RB} & VL24_CSR ) | ( VL24{R} & VL1714_PR & 468B & 468C & 468D & 468E & TC & TE & TF ))
458_CSR relay Seven Sisters P5 ( 458_CSR | ( TN & TS ) ) & TU & 458A & 458B & 458C & 458D
456_CSR relay Seven Sisters P5 HS45614/36D ( 456_CSR | ( 458B & 458C ) ) & 458D & 456A & 456B & 456C & 456D & 456E
dTE_R relay Seven Sisters P5 HS45615/44B dTE
dTG_R relay Seven Sisters P5 dTG
VL1714_PR relay Seven Sisters P5 HS45611/176 VL17{N} & VL14{N} & ( VL16{N} | VL13{R} )
TE_JR relay Seven Sisters P5 60 HS45615/45 !TE & TC
VL1008_PR relay Seven Sisters P5 HS45611/176D VL14{R} & VL15{R} & VL16{N} & VL17{R} & RH & RJ & RK & RL & SU
Specia TPRs For browser diagrams
470CDE468A relay For Browser 470C & 470D & 470E & 468A
TLTMTNTS relay For Browser TL & TM & TN & TS
458ABCD relay For Browser 458A & 458B & 458C & 458D
QZQYQXQW relay For Browser QZ & QY & QX & QW
451CBA relay For Browser 451C & 451B & 451A
449EDC relay For Browser 449E & 449D & 449C
QEQD relay For Browser QE & QD
SEVEN SISTERS PM LOGIC
VLS1{IDstore} attr Seven Sisters tdstore CS446965/30B id464B
VLS1{IDstorecanc} attr Seven Sisters tdcanc CS446965/30B VL22{RB} & !ST Should be: !SU
VLS1{TD} attr return "ACD" if VLS1{ID} eq "1"; return "BCD" if VLS1{ID} eq "2"; return "C" if VLS1{ID} eq "3"; return "B" if VLS1{ID} eq "4"; return "A" if VLS1{ID} eq "5"; return "ABD" if VLS1{ID} eq "6"; return "ABC" if VLS1{ID} eq "7"; return "D" if VLS1{ID} eq "8"; return "";
VLS1{691} attr TD contains A VLS1{TD} =~ /A/
VLS1{692} attr TD contains B VLS1{TD} =~ /B/
VLS1{693} attr TD contains C VLS1{TD} =~ /C/
VLS1{694} attr TD contains D VLS1{TD} =~ /D/
VLS1{mode} attr PM mode return "PB" if VLS1{YUPR} eq "1"; return "FCFS" if VLS1{562} eq "1"; return "PMonly" if VLS1{558} eq "1"; return "PM";
VLS1{311} attr TN non zero VLS1{extcantrn} != 0
VLS1{330} attr TN Coincidence ( VLS1{regTN} eq VLS1{extcantrn} ) & !VL_582
VLS1{332} attr TN Non-Coincidence !( VLS1{regTN} eq VLS1{extcantrn} ) | ( !VLS1{116} & VL_582 )
VLS1{361} attr TD Coincidence VLS1{TD} eq VLS1{regTD}
VLS1{365} attr TD Non-Coincidence VLS1{TD} =~ /^[ABCD]+$/
VLS1{377} attr Special PM Roll hole 17 VLS1{regHOLE17}
VLS1{step} attr Seven Sisters Step HS45611/351K VLS1_MAN_STEP | VLS1{410} | ( !VLS1{328} & VLS1{330} & VLS1{536} & !VLS1{124} ) | ( VL31J11 & VLS1{332} ) | ( VLS1{377} & !VLSB{475} ) | ( VL31J14 & !VLS1{122} & !VLS1{131} & !VLS1{124} & !VLS1{571} ) | ( VLS1{step} & VLS1{121} )
VL31J11 relay HS45611/351K ( VLS1{611} & VLS1{225} ) | ( VLS1{612} & VLS1{226} ) | ( VLS1{613} & VLS1{224} )
VL31J14 relay HS45611/351K VL31J14_2 | VL31J14_3 | VL31J14_4
VL31J14_2 relay HS45611/351K VLS1{613} & !VLS1{224} & VLS1{319} & VLS1{437} & !VLS1{427}
VL31J14_3 relay HS45611/351K VL20{N} & VLS1{613} & !VLS1{224} & VLS1{319} & !VL20G & !RJ & VLS1{605}
VL31J14_4 relay HS45611/351K !VL22BG & !ST & VL31J13 & !SU & !VLS1{606}
VL31J13 relay HS45611/351K ( VL13{R} & !VL22{N} & !VLS1{226} ) | ( !VLS1{640} & VL13{N} & !VLS1{224} ) | ( VL13{N} & !VLS1{225} & VLS1{640} )
VLS1{113} attr Seven Sisters Forward Drive Relay Repeater Done by PM HS45611/ 0
VLS1{116} attr Seven Sisters Contact bar repeater Done by PM HS45611/ 0
VLS1{130} attr HS45611/351K ( !VLS3{123} & VLS1{124} ) | ( VLS1{124} & VLS1{130} )
VLS1{131} attr Seven Sisters HS45611/351K VLS1{116} | ( !VL22{N} & !SU & VLS1{131} ) | ( VLS1{437} & VLS1{131} ) | ( !RJ & !VL20{N} & VLS1{131} )
VLS1{160} attr Seven Sisters Special Drive Relay REMOVED? HS45611/354F ( VL7G & !RL & VLS1{605} ) | ( VLS1{160} & !VLS1{427} & !VLS1{124} )
VLS1{201} attr storage input CORRECT? HS45611/356G VLS1{124}
VLS1{203} attr storage input CORRECT? HS45611/356G VLS1{124}
VLS1{319} attr Seven Sisters Train cancel guard HS45611/ ( VLS1{629} & VLS1{534} ) | ( VLS1{332} & VLS1{629} )
VLS1{328} attr Seven Sisters HS45611/351K ( VLS1{113} & VLS1{330} & VLS1{536} ) | ( VLS1{328} & VLS1{536} ) | ( VLS1{311} & VLS1{328} )
VLS1{410} attr Seven Sisters Time coincidence (No time on VLS1) HS45611/354F ( VLS1{410} & VLS1{124} ) | ( VLS1{124} & VLS3{124} & VLS3{113} & VLS3{410} )
VLS1{427} attr Seven Sisters Time delay 92 seconds? HS45611/354F VLS1_427_JR
VLS1_427_JR relay Seven Sisters TIMER 2 HS45611/354F VLS1{437}
VLS1_430_JR relay Seven Sisters Siding timer 240 HS45611/353D ( !SQ & SP & SU ) | ( SU & SP & !ST )
VLS1{431} attr Seven Sisters Siding layover timer relay HS45611/353D VLS1_430_JR
VLS1{437} attr Seven Sisters Time delay control relay HS45611/354F ( VL22{N} & VLS1{160} ) | ( VLS1{160} & VLS1{437} )
VLS1{571} attr Seven Sisters Extra train guard relay (inverted) HS45611/351K VLS1{561} | ( !SU & VLS1{571} ) | ( !ST & VLS1{571} & !VLS1{124} )
VLS1{584} attr Seven Sisters Remote PM Only control relay ERROR ON SHEET HS45611/353D ( VLS1{558} & !VLS1{571} & !VL_583 ) | ( !VL_583 & VLS1{563} ) | VL_584
VLS1{605} attr Seven Sisters Train O.O.T stick route 1 HS45611/354F ( VLS4{614} & !VLS4{571} & !RE & VL6G & VL13{N} & VL12{N} ) | ( RL & VLS1{605} & VL20{N} & !VLS1{124} ) | ( !VLS1{124} & !RK & VLS1{605} )
VLS1{606} attr Seven Sisters Train O.O.T stick route 2 HS45611/354F ( VLS4{613} & VL13{R} & VL6G & !RE & VLS4{571} ) | ( VL22{N} & VLS1{606} & !VLS1{124} ) | ( !VLS1{124} & !ST & VLS1{606} ) | ( VLS1{606} & !SU )
VLS1{629} attr Seven Sisters Special Guard Relay HS45611/353D ( !VLS1{113} & !VLS1{116} & VLSB{475} ) | ( !VLS1{113} & !VLS1{116} & !VLS1{377} )
VLS1{632} attr Seven Sisters Route Confirming Relay HS45611/
VLS1{633} attr Seven Sisters Route Guard Relay HS45611/
VLS1{639} attr Seven Sisters Train approach stick 2 HS45611/353D ( ST & VLS1{639} & !VLS1{124} ) | ( !464A & !464B )
VLS1{640} attr Seven Sisters Train approach relay HS45611/353D VLS1{639} | ( !VLS1{124} & SU & VLS1{640} ) | ( VLS1{640} & VL13{N} & !VLS1{124} & SV )
VLS1{661} attr Seven Sisters Route 1 stick relay HS45611/353D ( ( ST | VLS1{640} ) & VLS1{605} & VLS1{606} ) | ( VLS1{661} & VLS1{605} )
VLS1{662} attr Seven Sisters Route 2 stick relay HS45611/353D ( ( RK | !VL7{N} ) & VLS1{606} & !VLS1{605} ) | ( VLS1{662} & VLS1{606} )
VLS1{673} attr Seven Sisters TD route relay facing junction route 1 HS45611/354F VLS1{691} & ( ( VLS1{692} & VLS1{694} & !VLS1{693} ) | ( !VLS1{692} & !VLS1{693} & !VLS1{694} ) | ( VLS1{692} & VLS1{693} ) )
VLS1{674} attr Seven Sisters TD route relay facing junction route 2 HS45611/354F ( !VLS1{692} & VLS1{693} ) | ( VLS1{692} & VLS1{693} & VLS1{694} )
VLS1{562} attr Seven Sisters FROM REGULATOR - FCFS HS45611/352E ( !VL_582 & VLS1_REG_FCFS ) | VL_583
VLS1{YUPR} attr Seven Sisters FROM REGULATOR - PB HS45611/352E VL_YU_MASTER & VLS1_REG_PB & !VL_582
VLS1{534} attr Seven Sisters FROM REGULATOR - Extra Train HS45611/352E VLS1_REG_EXT_TRAIN & !VL_582
VLS1{563} attr Seven Sisters FROM REGULATOR - PM Acknowledge HS45611/352E ( VLS1_REG_PM_ACK | VLS1{563} ) & VLS1{566}
VLS1{558} attr Seven Sisters FROM REGULATOR - PM Only HS45611/352E VLS1_REG_PM_ONLY
VLS1{536} attr Seven Sisters FROM REGULATOR - Train cancel HS45611/352E VLS1_REG_TRAIN_CANCEL
VLS1{529} attr Seven Sisters FROM REGULATOR - Immediate extra train HS45611/352E VLS1_REG_IMMED_EXT_TRAIN
VLS1{566} attr Seven Sisters TO REGULATOR - Out Of Agreement & PM Ack Stick HS45611/352E ( SU & VLS1{563} & !VLS1{124} ) | ( !VLS1{562} & VL31D4 & SU & VLS1{319} & !VLS1{584} & VLS1{365} & ( VL13{N} | VL6{N} ) & !VLS1{361} & !VLS1{606} )
VL31D4 relay Seven Sisters ^^^^ HS45611/352E ( !VLS1{225} & VLS1{611} ) | ( !VLS1{226} & VLS1{612} )
VLS1{586} attr Seven Sisters TO REGULATOR - TD No code HS45611/352E VL22{N} & ( !SP | !SQ ) & !VLS1{365} & SU & VLS1{640}
VLS1{561} attr Seven Sisters TO REGULATOR - Extra Train See 358 HS45611/352E ( VLS1{561} & SU & !VLS1{124} ) | ( !VLS1{124} & VLS1{561} & !VL22BG ) | ( VLS1{534} & VLS1{113} & VLS1{330} ) | ( VLS1{529} & VLS1{534} & SU )
VLS1{546} attr Seven Sisters TO REGULATOR - Train Cancel HS45611/352E VLS1{328}
VLS1{567} attr Seven Sisters 567-569? TO REGULATOR - Storage HS45611/352E VLS1{224} | VLS1{225} | VLS1{226}
VLS1{PM224store:VLS1{regTN}} attr Seven Sisters HS45611/352E VL31G8_2 | VL31G8_3 | VL31G8_4
VL31G8_2 relay HS45611/352E !VLS1{427} & VLS1{437} & !VLS1{131} & ( VLS1{611} | VLS1{612} )
VL31G8_3 relay HS45611/352E VL20G & !RJ & VLS1{605} & ( VLS1{611} | VLS1{612} )
VL31G8_4 relay HS45611/352E !VLS1{606} & !VLS1{571} & VL13{N} & VL22BG & !SU & ( VLS1{611} | VLS1{612} ) & !VLS1{640}
VLS1{PM225store:VLS1{regTN}} attr Seven Sisters HS45611/352E !VLS1{571} & !SU & VL13{N} & !VLS1{606} & VL22BG & ( ( VLS1{640} & VLS1{612} ) | ( VLS1{613} & VLS1{640} ) )
VLS1{PM226store:VLS1{regTN}} attr Seven Sisters HS45611/352E !VLS1{571} & !SU & VL13{R} & VL22BG & ( VLS1{611} | VLS1{613} )
VLS1{PM224storecanc} attr Seven Sisters HS45611/352E VLS1{113} & VLS1{224} & VLS1{332} & VLS1{613}
VLS1{PM225storecanc} attr Seven Sisters HS45611/352E VLS1{113} & VLS1{225} & VLS1{332} & VLS1{611}
VLS1{PM226storecanc} attr Seven Sisters HS45611/352E VLS1{113} & VLS1{226} & VLS1{332} & VLS1{612} & ( VLSB{475} | ( !VLSB{475} & !VLS1{377} ) )
VLS2{mode} attr PM mode return "PB" if VLS2{YUPR} eq "1"; return "FCFS" if VLS2{562} eq "1"; return "PMonly" if VLS2{558} eq "1"; return "PM";
VLS2{311} attr TN non zero VLS2{extcantrn} != 0
VLS2{328} attr Seven Sisters HS45611/355H ( VLS2{113} & VLS2{330} & VLS2{536} ) | ( VLS2{328} & VLS2{536} ) | ( VLS2{311} & VLS2{328} )
VLS2{330} attr TN Coincidence ( VLS2{regTN} eq VLS2{extcantrn} ) & !VL_582
VLS2{332} attr TN Non-Coincidence !( VLS2{regTN} eq VLS2{extcantrn} ) | ( !VLS2{116} & VL_582 )
VLS2{361} attr TD Coincidence VLS2{TD} eq VLS2{regTD}
VLS2{365} attr TD Non-Coincidence VLS2{TD} =~ /^[ABCD]+$/
VLS2{IDstore} attr Seven Sisters tdstore CS46965/32C id443E
VLS2{IDstorecanc} attr Seven Sisters tdcanc CS46965/32C !453B & 453A
VLS2{TD} attr return "BCD" if VLS2{ID} eq "1"; return "ACD" if VLS2{ID} eq "2"; return "ABC" if VLS2{ID} eq "3"; return "C" if VLS2{ID} eq "4"; return "D" if VLS2{ID} eq "5"; return "B" if VLS2{ID} eq "6"; return "A" if VLS2{ID} eq "7"; return "ABD" if VLS2{ID} eq "8"; return "";
VLS2{691} attr TD contains A VLS2{TD} =~ /A/
VLS2{692} attr TD contains B VLS2{TD} =~ /B/
VLS2{693} attr TD contains C VLS2{TD} =~ /C/
VLS2{694} attr TD contains D VLS2{TD} =~ /D/
VLS2{step} attr Seven Sisters Step HS45611/356G VLS2_MAN_STEP | VLS2{410} | ( !VLS2{328} & VLS2{330} & VLS2{536} & !VLS2{124} ) | ( !VLS2{124} & VL37J9 & !VLS2{122} )
VL37J9 relay Step HS45611/356G ( VLS2{611} & VLS2{225} & VLS2{332} ) | ( VLS2{612} & VLS2{226} & VLS2{332} ) | VL37J5
VL37J5 relay Step HS45611/356G !VLS2{131} & VL37J10 & !VLS2{571} & !VL1G & !453B & QA
VL37J10 relay Step HS45611/356G ( !VLS2{225} & VL10{N} ) | ( !VLS2{226} & VL10{R} )
VLS2{130} attr Seven Sisters HS45611/356G ( !VLS6{123} & VLS2{124} ) | ( VLS2{124} & VLS2{130} )
VLS2{131} attr Seven Sisters HS45611/356G ( VLS2{116} & !453B ) | ( !453B & VLS2{131} )
VLS2{303} attr Seven Sisters HS45611/357D VLS2_303_JR
VLS2_303_JR relay Seven Sisters Timer 60 HS45611/357D !VLS2{YUPR} & 453B & !VLS2{584} & !VLS2{571} & VLS2{365} & !VLS2{361} & !VLS2{124} & !VLS2{116}
VLS2{319} attr Seven Sisters HS45611/355H VLS2{534} | VLS2{332}
VLS2{366} attr Seven Sisters HS45611/357D VLS2{303} | VLS2{562} | ( !VLS2{YUPR} & VLS2{366} & VL1G )
VLS2{410} attr Seven Sisters Time Coincidence (No time on VLS2) HS45611/357D ( VLS6{124} & VLS6{113} & VLS6{410} & VLS2{124} ) | ( VLS2{124} & VLS2{410} )
VLS2{571} attr Seven Sisters HS45611/356G VLS2{561} | ( VL1G & VLS2{571} ) | ( VLS2{571} & !453B )
VLS2{584} attr Seven Sisters HS45611/357D ( !VLS2{571} & VLS2{558} & !VL_583 ) | ( !VL_583 & VLS2{563} ) | VL_584
VLS2{640} attr Seven Sisters Train approach relay HS45611/357D !( 449C & 449D & 449E ) | !( 451A & 451B & 451C ) | !453A
VLS2{673} attr Seven Sisters TD route relay facing junction route 1 HS45611/357D ( VLS2{691} & !VLS2{692} & !VLS2{693} ) | ( !VLS2{691} & VLS2{692} & !VLS2{694} )
VLS2{674} attr Seven Sisters TD route relay facing junction route 2 HS45611/357D ( !VLS2{691} & !VLS2{692} & VLS2{693} ) | ( !VLS2{691} & !VLS2{692} & VLS2{694} )
VLS2{675} attr Seven Sisters TD route relay facing junction route 3 HS45611/357D VLS2{691} & VLS2{692} & VLS2{693}
VLS2{562} attr Seven Sisters FROM REGULATOR - FCFS HS45611/356G ( !VL_582 & VLS2_REG_FCFS ) | VL_583
VLS2{YUPR} attr Seven Sisters FROM REGULATOR - PB HS45611/356G VL_YU_MASTER & VLS2_REG_PB & !VL_582
VLS2{534} attr Seven Sisters FROM REGULATOR - Extra Train HS45611/356G VLS2_REG_EXT_TRAIN & !VL_582
VLS2{563} attr Seven Sisters FROM REGULATOR - PM Acknowledge HS45611/356G ( VLS2_REG_PM_ACK | VLS2{563} ) & VLS2{566}
VLS2{558} attr Seven Sisters FROM REGULATOR - PM Only HS45611/356G VLS2_REG_PM_ONLY
VLS2{536} attr Seven Sisters FROM REGULATOR - Train cancel HS45611/356G VLS2_REG_TRAIN_CANCEL
VLS2{529} attr Seven Sisters FROM REGULATOR - Immediate extra train HS45611/356G VLS2_REG_IMMED_EXT_TRAIN
VLS2_566_DELAY_JR relay Seven Sisters TO REGULATOR - Out Of Agreement & PM Ack Stick 0.5 HS45611/356G ( !VLS2{124} & VLS2{563} & 453B ) | ( VL37E4 & !VLS2{366} & VLS2{319} & !VLS2{584} & VLS2{365} & !VLS2{361} )
VL37E4 relay Seven Sisters ^^^^ HS45611/356G ( VLS2{611} & !VLS2{225} ) | ( VLS2{612} & !VLS2{226} )
VLS2{566} attr Seven Sisters TO REGULATOR - Out Of Agreement & PM Ack Stick VLS2_566_DELAY_JR
VLS2{586} attr Seven Sisters TO REGULATOR - TD No code HS45611/356G !VL1{R} & VLS2{640} & !VLS2{365} & !VLS2{584} & 453B
VLS2{569} attr Seven Sisters 567-569? TO REGULATOR - Storage HS45611/356G VLS2{225} | VLS2{226}
VLS2{546} attr Seven Sisters TO REGULATOR - Train Cancel HS45611/356G VLS2{328}
VLS2{561} attr Seven Sisters TO REGULATOR - Extra Train See 358 HS45611/356G ( VLS2{529} & 453B & VLS2{534} ) | ( VLS2{534} & VLS2{113} & VLS2{330} ) | ( !VL1G & VLS2{561} & !VLS2{124} ) | ( VLS2{561} & 453B & !VLS2{124} )
VL24{673} attr Seven Sisters VLP5{TD} eq "D" | VLP5{TD} eq "C"
VL24{633} attr Seven Sisters Route Guard Relay HS45611/361L ( !TG & VL24{633} ) | ( !TF & VL24{633} ) | ( !TE & VL24{633} ) | ( !TC & VL17{N} & !TE )
VL22{633} attr Seven Sisters Route Guard Relay HS45611/361L ( VL19G & VL14{N} & !TC ) | ( !VLS3{124} & TH & TJ & VL22{633} & VL14{N} ) | ( VL22{633} & !TG & VL14{N} & !VLS3{124} )
VL20{633} attr Seven Sisters Route Guard Relay HS45611/361L ( VL19G & VL14{R} & !TC ) | ( !VLS3{124} & TH & TJ & VL20{633} ) | ( VL20{633} & !TG & !VLS3{124} )
VLP5{645} attr Seven Sisters Route to P5 HS45611/360J ( TC & TF & TE & TG ) | ( TC & TE & VLS3{131} ) | ( TC & TE & VLS3{571} & !( TH & TJ ) )
VLS2{PM225store:VLS2{regTN}} attr Seven Sisters HS45611/352E VL10{N} & VLS2{612} & !VLS2{571} & VL1G & !453B
VLS2{PM226store:VLS2{regTN}} attr Seven Sisters HS45611/352E !453B & VL1G & !VLS2{571} & VLS2{611} & VL10{R}
VLS2{PM225storecanc} attr Seven Sisters HS45611/352E VLS2{113} & VLS2{225} & VLS2{332} & VLS2{611}
VLS2{PM226storecanc} attr Seven Sisters HS45611/352E VLS2{113} & VLS2{226} & VLS2{332} & VLS2{612}
VLSB{IDstore} attr CS46965/34E idWP
VLSB{IDstorecanc} attr CS46965/34E 468D & !468E was: !TE & TF & VL24{RB}
VLSV{IDstore} attr CS46965/35H idSV | idSVa
VLSV{IDstorecanc} attr !TE & TF & VL19{RB}
VLRG{IDstore} attr CS46965/31/1F idRG
VLRG{IDstorecanc} attr AS VLS4 cancel CS46965/31/1F !VL6{RB} & !RD & RC should be: VL6{RB} & !RE
VLRK{IDstore} attr CS46965/33E idRK
VLRK{IDstorecanc} attr TC 'RQ' from HS45611/433A f25/5 CS46965/33E !RQ
VLRK{TD} attr To Depot Control HS43572/48 CS46965/33E return "C" if VLRK{ID} eq "4"; return "D" if VLRK{ID} eq "5"; return "";
VLS3{mode} attr PM mode return "PB" if VLS3{YUPR} eq "1"; return "FCFS" if VLS3{562} eq "1"; return "PMonly" if VLS3{558} eq "1"; return "PM";
VLS3{311} attr TN non zero VLS3{extcantrn} != 0
VLS3{330} attr TN Coincidence ( VLS3{regTN} eq VLS3{extcantrn} ) & !VL_582
VLS3{332} attr TN Non-Coincidence !( VLS3{regTN} eq VLS3{extcantrn} ) | ( !VLS3{116} & VL_582 )
VLS3{361} attr TD Coincidence VLS3{TD} eq VLS3{regTD}
VLS3{365} attr TD Non-Coincidence VLS3{TD} =~ /^[ABCD]+$/
VLS3{377} attr Special PM Roll hole 17 VLS3{regHOLE17}
VLS3{IDstore:VLSB{ID}} attr RTU1 (via VL24G) CS46965/35H !468E & TC & VL24{AC} should be 468E & ( !468D | !468C | !468B ) & VL24{RB}
VLS3{IDstore:VLSV{ID}} attr RTU2 (via VL19G) CS46965/35H TE & !TC & VL19{AC} should be !SV & VL8{N}
VLS3{IDstorecanc} attr CS46965/35H ( !TH & VL18{RB} ) | ( !TC & VL8{RB} ) should be ( !( TH & TJ ) & VL18{RB} ) | ( !TC & VL8{RB} ) New version cancelled by previous train leaving
VLSB{TD} attr return "ACD" if VLSB{ID} eq "1"; return "BCD" if VLSB{ID} eq "2"; return "C" if VLSB{ID} eq "3"; return "B" if VLSB{ID} eq "4"; return "A" if VLSB{ID} eq "5"; return "ABD" if VLSB{ID} eq "6"; return "ABC" if VLSB{ID} eq "7"; return "D" if VLSB{ID} eq "8"; return "";
VLSB{691} attr TD contains A VLSB{TD} =~ /A/
VLSB{692} attr TD contains B VLSB{TD} =~ /B/
VLSB{693} attr TD contains C VLSB{TD} =~ /C/
VLSB{694} attr TD contains D VLSB{TD} =~ /D/
VLS3{TD} attr return "ACD" if VLS3{ID} eq "1"; return "BCD" if VLS3{ID} eq "2"; return "C" if VLS3{ID} eq "3"; return "B" if VLS3{ID} eq "4"; return "A" if VLS3{ID} eq "5"; return "ABD" if VLS3{ID} eq "6"; return "ABC" if VLS3{ID} eq "7"; return "D" if VLS3{ID} eq "8"; return "";
VLS3{691} attr TD contains A VLS3{TD} =~ /A/
VLS3{692} attr TD contains B VLS3{TD} =~ /B/
VLS3{693} attr TD contains C VLS3{TD} =~ /C/
VLS3{694} attr TD contains D VLS3{TD} =~ /D/
VLS3{step} attr Seven Sisters HS45611/358J VLS3_MAN_STEP | ( VLS3{410} & VLS3{124} & VLS1{124} ) | ( VLS3{536} & VLS3{330} & !VLS3{124} & !VLS3{328} ) | VL33J16_4 | ( VLS3{stepDISABLED} & VLS3{121} )
VL33J16_4 relay HS45611/358J VL33J11_4 | VL33J9_4 | ( !VLSB{475} & VLS3{377} )
VL33J11_4 relay Storage and non-coincidence HS45611/358J ( ( VLS3{611} & VLS3{221} ) | ( VLS3{612} & VLS3{222} ) | ( VLS3{613} & VLS3{220} ) | ( VLS3{614} & VLS3{225} ) ) & VLS3{332}
VL33J9_4 relay HS45611/358J !VLS3{571} & !VLS3{124} & !VLS3{131} & !VLS3{122} & ( ( !VL8G & !VL8{N} & !TC & VL24{633} & !VLS3{225} ) | ( !VL18G & !( TH & TJ ) & VL33J14 ) )
VL33J14 relay HS45611/358J ( !TG & !VLS3{221} & VL24{633} ) | VL33J14_3 | VL33J14_4
VL33J14_3 relay HS45611/358J !VLS3{222} & ( ( VLS3{160} & VL20{633} ) | VL22{633} )
VL33J14_4 relay HS45611/358J !VLS3{220} & ( ( VLS3{161} & VL22{633} ) | VL20{633} )
VLS3{131} attr Seven Sisters HS45611/358J ( VLS3{116} & !( TH & TJ ) ) | ( !( TH & TJ ) & VLS3{131} ) | ( VLS3{116} & !TC ) | ( !TC & VLS3{131} )
VLS3{132} attr Seven Sisters HS45611/358J ( TC & TH & TJ ) | ( TH & TJ & VL8{N} )
VLS3{160} attr Seven Sisters HS45611/361L ( VL19G & VLS3{605} & !TC & VL14{R} ) | ( VLS3{160} & VL20{633} )
VLS3{161} attr Seven Sisters HS45611/361L ( VL19G & VLS3{606} & !TC & VL14{N} ) | ( VLS3{161} & VL22{633} )
VLS3{211} attr Seven Sisters Permission to run out of turn 1 request HS45611/361L ( VLS3{211} & VLS3{1001} & TE ) | ( TE & ( VL33E7_3 | VL33E7_4 ) & VLS3{1001} & !VLS3{561} & VLP5{645} & VL17{N} & VL20{N} & VLS3{410} & !VL22_1U_PMCALL & !( 468D & 468C & 468B & 468A ) & VLS3{625} & VL24{N} )
VL33E7_3 relay HS45611/361L ( !VLS1{613} | !VLS3{431} | !VLS1{661} ) & ( ( !VLS1{640} & !VLS1{431} ) | VLS1{YUPR} ) & !VLS3{222} & VLS3{612} & VLS3{319}
VL33E7_4 relay HS45611/361L ( VLS1{YUPR} | VLS1{431} | !VLS1{662} ) & !VLS3{431} & !VLS3{220} & VLS3{613} & VLS3{319}
VLS3{212} attr Seven Sisters Permission to run out of turn 2 request HS45611/361L ( VLS3{1001} & VLS3{424} & VLS3{211} ) | ( VLS3{212} & !VLP5{645} & VLS3{1001} )
VLS3_303_JR relay Seven Sisters 60 HS45611/360J !VLS3{116} & !VLS3{124} & !VLS3{584} & !VLS3{YUPR} & !VLS3{571} & VLS3{588} & !VLS3{361} & VLS3{365}
VLS3{303} attr Seven Sisters HS45611/360J VLS3_303_JR
VLS3{319} attr Seven Sisters Train cancel guard HS45611/358J ( VLS3{534} & VLS3{629} ) | ( VLS3{629} & VLS3{332} )
VLS3{328} attr Seven Sisters Train cancel coincidence stick relay HS45611/358J ( VLS3{113} & VLS3{330} & VLS3{536} ) | ( VLS3{328} & VLS3{536} ) | ( VLS3{311} & VLS3{328} )
VLS3{366} attr Seven Sisters T.D. Overriding control stick relay HS45611/360J VLS3{303} | ( VLS3{366} & !VLS3{YUPR} & VL18G & !VLS3{124} ) | ( VLS3{366} & !VLS3{YUPR} & VL8G )
VLS3_404_JR relay Seven Sisters 1 min timer 60 HS45611/360J VLS3{211}
VLS3{410} attr Seven Sisters Time coincidence (VLS3 has time on roll - compare with real time) FUDGE HS45611/361L ( ( SYSTEM{systime} > VLS3{regOTIME} ) & !VLS3{116} ) | VLS3_OVERRIDE_TIME_COINC
VLS3{424} attr Seven Sisters Route selection control delay relay HS45611/360J VLS3_404_JR | VLS3{654}
VLS3_430_JR relay Seven Sisters Siding delay unit 230 Should be 240… HS45611/360J ( RJ | VL13{R} ) & !RK & VL7{N} Maybe ( RJ | VL13{R} ) & !RK & VL7{N} to stop R63-bound trains cancelling Shortened so train reversal and PM departure happens before a permission to run OOT is sought (and VLS3{520}/{526} triggering) Orig: RJ & !RK & VL7{N}
VLS3{430} attr Seven Sisters Siding delay unit HS45611/360J VLS3_430_JR
VLS3{431} attr Seven Sisters Siding time delay HS45611/360J VLS3{430}
VLS3{571} attr Seven Sisters Extra train guard relay HS45611/358J VLS3{561} | ( VL18G & VLS3{571} ) | ( !( TH & TJ ) & VLS3{571} ) | ( !TC &VLS3{571} ) | ( VL8G & VLS3{571} )
VLS3{583} attr Seven Sisters Remote overriding relay FCFS HS45611/360J ( VLS3{558} & !VLS3{571} & !VL_583 ) | !VLS3{563} | VL_584
VLS3{584} attr Seven Sisters Remote PM Only control relay ERROR ON SHEET HS45611/360J ( VLS3{558} & !VLS3{571} & !VL_583 ) | ( !VL_583 & VLS3{563} ) | VL_584
VLS3{588} attr Seven Sisters Special T.D. Out Of Agreement warning cut-off relay HS45611/361L ( !VL8G & TH & TJ ) | TG | !TC
VLS3{605} attr Seven Sisters Train O.O.T stick route 1 HS45611/361L VLS1{605} | ( VLS3{605} & !VL20{N} & TE )
VLS3{606} attr Seven Sisters Train O.O.T stick route 2 HS45611/361L VLS1{606} | ( VLS3{606} & !VL22{N} & TE )
VLS3{625} attr Seven Sisters Permission HS45611/361M ( VL6{N} & RK & !VL6_2U_PMCALL ) | ( RK & VL12{R} ) | ( RK & VL13{R} ) | VLS4{679} | VLS3_625_OVERRIDE
VLS3{629} attr Seven Sisters Special Guard Relay HS45611/360J ( !VLS3{113} & !VLS3{116} & VLSB{475} ) | ( !VLS3{113} & !VLS3{116} & !VLS3{377} )
VLS3{659} attr Seven Sisters Train Out Of Turn (trailing route 1) HS45611/361L ( VLS3{659} & !VL20{633} & !VL22{633} & VLS3{1001} ) | ( VLS3{211} & 468E & VLS3{424} )
VLS3{673} attr Seven Sisters TD route relay facing junction route 1 HS45611/358J ( ( VLS3{694} & VLS3{692} & !VLS3{693} ) | ( !VLS3{692} & !VLS3{693} & !VLS3{694} ) | ( VLS3{692} & VLS3{693} & !VLS3{694} ) ) & VLS3{691}
VLS3{674} attr Seven Sisters TD route relay facing junction route 2 HS45611/358J ( ( !VLS3{691} & !VLS3{692} & VLS3{693} ) | ( VLS3{692} & VLS3{693} & VLS3{694} ) )
VLS3{1001} attr Seven Sisters Fixed 562/124 which were not negated HS45611/360J !VLS3{YUPR} & !VLS3{562} & !VLS3{526} & !VLS3{584} & !VLS3{124} & !VL_582
VLS3{1002} attr Seven Sisters HS45611/360J ( VLS3{562} & VLP5{645} ) | ( VLS3{673} & VLS3{561} & !VLP5{645} ) | ( VLP5{645} & !VLS3{561} & !VLS3{562} )
VLS3{1206} attr Seven Sisters HS45611/360J VL6{N} | VL12{R}
VLS3{562} attr Seven Sisters FROM REGULATOR - FCFS HS45611/359L ( !VL_582 & VLS3_REG_FCFS ) | VL_583
VLS3{YUPR} attr Seven Sisters FROM REGULATOR - PB HS45611/359L VL_YU_MASTER & VLS3_REG_PB & !VL_582
VLS3{534} attr Seven Sisters FROM REGULATOR - Extra Train HS45611/359L VLS3_REG_EXT_TRAIN & !VL_582
VLS3{526} attr Seven Sisters FROM REGULATOR - No out of turn HS45611/359L ( VLS3_REG_NOOT | VLS3{526} ) & VLS3{520}
VLSB{475} attr Seven Sisters FROM REGULATOR - SB Engineers Test HS45611/359L VLSB_REG_ENG_TRAIN
VLS3{529} attr Seven Sisters FROM REGULATOR - Immediate extra train HS45611/359L VLS3_REG_IMMED_EXT_TRAIN
VLS3{536} attr Seven Sisters FROM REGULATOR - Train cancel HS45611/359L VLS3_REG_TRAIN_CANCEL
VLS3{558} attr Seven Sisters FROM REGULATOR - PM Only HS45611/359L VLS3_REG_PM_ONLY
VLS3{563} attr Seven Sisters FROM REGULATOR - PM Acknowledge HS45611/359L ( VLS3_REG_PM_ACK | VLS3{563} ) & VLS3{566}
VLS3_566_DELAY_JR relay Seven Sisters TO REGULATOR - Out Of Agreement & PM Ack Stick 0.5 HS45611/359L ( !VLS3{584} & VLS3{319} & !VLS3{361} & !VLS3{366} & VLS3{365} & !VLS3{562} & VL32B19 & VLS3{588} ) | ( VLS3{563} & VLS3{588} )
VL32B19 relay Seven Sisters ^^^^ HS45611/359L ( !VLS3{221} & VLS3{611} ) | ( !VLS3{222} & VLS3{612} ) | ( !VLS3{220} & VLS3{613} ) | ( !VLS3{225} & VLS3{614} )
VLS3{566} attr TO REGULATOR - Out Of Agreement & PM Ack Stick VLS3_566_DELAY_JR
VLS3_586_DELAY_JR relay Seven Sisters DELAY 0.5 HS45611/359L ( !TC | !TE | !TF | !TG ) & VL8{N} & VL18{N} & !VLS3{365}
VLS3{586} attr Seven Sisters TO REGULATOR - TD No code VLS3_586_DELAY_JR
VLS3{567} attr Seven Sisters 567-569? TO REGULATOR - Storage HS45611/359L VLS3{221} | VLS3{222} | VLS3{220} | VLS3{225}
VLS3{561} attr Seven Sisters TO REGULATOR - Extra Train See 358 HS45611/358J ( !VLS3{124} & VL33B2 ) | ( VLS3{529} & VLS3{534} & VLS3{132} ) | ( VLS3{534} & VLS3{330} & VLS3{113} )
VL33B2 relay HS45611/358J ( VLS3{561} & TH & TJ & TC ) | ( TC & VLS3{561} & !VL18G ) | ( !VL18G & VLS3{561} & !VL8G ) | ( !VL8G & VLS3{561} & TH & TJ )
VLS3{546} attr Seven Sisters TO REGULATOR - Train Cancel HS45611/359L VLS3{328}
VLS3{520} attr Seven Sisters TO REGULATOR - Train OOT & NOOT stick HS45611/359L VLS3{211} | VLS3{212} | VLS3{424} | ( VLS3{526} & 468E )
VLS3{PM221store:VLS3{regTN}} attr Seven Sisters HS45611/359L !VLS3{571} & !( TH & TJ ) & VL18G & ( VLS3{612} | VLS3{613} | VLS3{614} ) & VL24{633}
VLS3{PM222store:VLS3{regTN}} attr Seven Sisters HS45611/359L VL33G18_3 | VL33G18_2
VL33G18_3 relay HS45611/359L ( VLS3{611} | VLS3{613} | VLS3{614} ) & VL18G & !( TH & TJ ) & VL20{633} & VLS3{160} & !VLS3{571}
VL33G18_2 relay HS45611/359L !VLS3{571} & VL22{633} & VL18G & ( VLS3{611} | VLS3{613} | VLS3{614} ) & !VLS3{161}
VLS3{PM220store:VLS3{regTN}} attr Seven Sisters HS45611/359L VL33F18_3 | VL33F18_2
VL33F18_3 relay HS45611/359L ( VLS3{611} | VLS3{612} | VLS3{614} ) & VL18G & !( TH & TJ ) & VLS3{161} & VL22{633} & !VLS3{571}
VL33F18_2 relay HS45611/359L !VLS3{571} & VL20{633} & VL18G & !( TH & TJ ) & ( VLS3{611} | VLS3{612} | VLS3{614} ) & !VLS3{160}
VLS3{PM225store:VLS3{regTN}} attr Seven Sisters HS45611/359L !VLS3{571} & !TC & VL8G & ( VLS3{611} | VLS3{612} | VLS3{613} ) & VL24{633}
VLS3{PM221storecanc} attr Seven Sisters HS45611/359L VLS3{113} & VLS3{221} & VLS3{332} & VLS3{611}
VLS3{PM222storecanc} attr Seven Sisters HS45611/359L VLS3{113} & VLS3{222} & VLS3{332} & VLS3{612}
VLS3{PM220storecanc} attr Seven Sisters HS45611/359L VLS3{113} & VLS3{220} & VLS3{332} & VLS3{613}
VLS3{PM225storecanc} attr Seven Sisters HS45611/359L VLS3{113} & VLS3{225} & VLS3{332} & VLS3{614} & ( VLSB{475} | ( !VLSB{475} & !VLS3{377} ) )
VLS4{mode} attr PM mode return "PB" if VLS4{YUPR} eq "1"; return "FCFS" if VLS4{562} eq "1"; return "PMonly" if VLS4{558} eq "1"; return "PM";
VLS4{311} attr TN non zero VLS4{extcantrn} != 0
VLS4{330} attr TN Coincidence ( VLS4{regTN} eq VLS4{extcantrn} ) & !VL_582
VLS4{332} attr TN Non-Coincidence !( VLS4{regTN} eq VLS4{extcantrn} ) | ( !VLS4{116} & VL_582 )
VLS4{361} attr TD Coincidence - includes special lamp on diagram ( VLS4{674} & VLS4{693} ) | ( VLS4{681} & VLS4{694} ) | ( VLS4{673} & VLS4{611} ) | ( VLS4{682} & !VLS4{693} & !VLS4{694} & VLS4{621} & !VLS4{116} )
VLS4{365} TD Non-Coincidence - exists? ( VLS4{TD} ne "" ) & !VLS4{361}
VLS4{377} attr Special PM Roll hole 17 VLS4{regHOLE17}
VLS4{691} attr Unused 0
VLS4{692} attr Unused 0
VLS4{693} attr Directly from PM HS45611/362H VLS4{regTD_C}
VLS4{694} attr Directly from PM HS45611/362H VLS4{regTD_D}
VLRG{IDconv} attr Required as SB RG levels are translated In CS46965/31/1F CS46965/31/1F return "6" if VLRG{ID} eq "1"; return "1" if VLRG{ID} eq "2"; return "2" if VLRG{ID} eq "3"; return "8" if VLRG{ID} eq "8"; return"";
VLS4{IDstore:VLS2{ID}} attr TD from Finsbury Park CONFIRMED CS46965/31/1F VL1{R} & VL10{R} & 453B & ( !( 451A & 451B & 451C ) | !453A )
VLS4{IDstore:VLRG{IDconv}} attr RTU2 TD from Depot/Sidings CONFIRMED CS46965/31/1F VL22{RB} & VL13{R} & !RE Should be: VL22{RB} & VL13{R} & !RG
VLS4{IDstorecanc} attr Knock down CONFIRMED CS46965/31/1F VL6{RB} & !RE
VLS4{TD} attr 1 from RG, rest from S2. ABC are SS reversers UNCONFIRMED CS46965/GUESSED return "BCD" if VLS4{ID} eq "1"; return "C" if VLS4{ID} eq "2"; return "ABC" if VLS4{ID} eq "3"; return "C" if VLS4{ID} eq "4"; return "D" if VLS4{ID} eq "5"; return "B" if VLS4{ID} eq "6"; return "A" if VLS4{ID} eq "7"; return "ABD" if VLS4{ID} eq "8"; return "";
VLP4{691} attr TD contains A correct name - using P4 as S4 in use? VLS4{TD} =~ /A/
VLP4{692} attr TD contains B correct name - using P4 as S4 in use? VLS4{TD} =~ /B/
VLP4{693} attr TD contains C correct name - using P4 as S4 in use? VLS4{TD} =~ /C/
VLP4{694} attr TD contains D correct name - using P4 as S4 in use? VLS4{TD} =~ /D/
VLS4{673} attr VL6_1U_PMCALL TD Route Relay Facing Junc Route 1 CS46965/41G VLS4{TD} eq"A" | VLS4{TD} eq"B" W 37AV5 "B: doesn't seem to be included - don't know why not
VLS4{674} attr VL6_2U_RUMIN TD Route Relay Facing Junc Route 2 CONFIRMED CS46965/41G VLS4{TD} eq"C" NPS 37AV8
VLS4{681} attr VL6_2U_RUMIN TD Route Relay Facing Junc Route 3 CONFIRMED CS46965/41G VLS4{TD} eq"D" NPE 37AV7
VLS4{682} attr VL6_2/3U_RUMIN TD Route Relay Facing Junc Route 4 CONFIRMED CS46965/41G VLS4{TD} eq"ABC" SS 37AV8
VL_STAFF_R relay CONFIRMED CS46965/41G VLS4{TD} eq"C" NPS 37AV8
VL_STOPS_HERE_R relay CONFIRMED CS46965/41G VLS4{TD} eq"ABC" | VLS4{TD} eq"C" | VLS4{TD} eq"D"
VLS4{step} attr HS45611/362H VLS4_MAN_STEP | VL39J10_1 | VL39J10_2 | VL39J10_3 | VL39J10_4
VL39J10_1 relay Storage step or second step HS45611/362H ( VLS4{612} & VLS4{226} & VLS4{332} ) | ( VLS4{613} & VLS4{226} & VLS4{332} ) | ( VLS4{611} & VLS4{225} & VLS4{332} ) | ( VLS4{614} & VLS4{226} & VLS4{332} ) | ( VLS4{377} & !VLNB{475} )
VL39J10_2 relay Normal northbound step when VL6 reversed HS45611/362H !RD & !RE & !VLS4{122} & !VL6{N} & !VLS4{131} & !VL6G & !VLS4{124} & !VLS4{571} & ( ( !VLS4{226} & VL12{N} ) | ( VLS4{661} & !VLS4{225} & VL12{R} ) )
VL39J10_3 relay HS45611/362H VLS4{330} & VLS4{536} & !VLS4{124} & !VLS4{328}
VL39J10_4 relay End of service HS45611/362H VLS4{124} & VLS4{410}
VLS4{130} attr Seven Sisters HS45611/362H ( !VLS4{123} & VLS4{124} ) | ( VLS4{124} & VLS4{130} )
VLS4{131} attr Seven Sisters HS45611/362H ( VLS4{116} & !RE & !VL6{N} ) | ( !VL6{N} & VLS4{131} & !RE )
VLS4_303_JR relay Seven Sisters 60 HS45611/363G !VLS4{YUPR} & !VLS4{571} & !VLS4{361} & !VLS4{116} & !VLS4{124} & !VLS4{584} & RE & ( VLS4{674} | VLS4{681} | VLS4{673} | VLS4{682} )
VLS4{303} attr Seven Sisters HS45611/363G VLS4_303_JR
VLS4{319} attr Seven Sisters HS45611/362H ( VLS4{629} & VLS3{534} ) | ( VLS4{629} & VLS4{332} )
VLS4{328} attr Seven Sisters HS45611/362H ( VLS4{113} & VLS4{330} & VLS4{536} ) | ( VLS4{536} & VLS4{328} ) | ( VLS4{311} & VLS4{328} )
VLS4{366} attr Seven Sisters HS45611/363G VLS4{303} | VLS4{562} | ( VLS4{YUPR} & VL6G & VLS4{366} )
VLS4_402_JR relay Seven Sisters 120 HS45611/363G ( VLS4{661} & !RB & RE ) | ( RE & !RC & VLS4{661} ) | ( RE & !RD & VLS4{661} )
VLS4{402} attr Seven Sisters HS45611/363G VLS4_402_JR
VLS4{414} attr Seven Sisters HS45611/363G VLS4_402_JR
VLS4{629} attr Seven Sisters HS45611/364P ( VLNB{475} & !VLS4{113} & !VLS4{116} ) | ( !VLS4{377} & !VLS4{113} & !VLS3{116} )
VLS4_404_JR relay Seven Sisters 60 HS45611/363G VLS4{211}
VLS4{404} attr Seven Sisters HS45611/363G VLS4_404_JR
VLS4{424} attr Seven Sisters HS45611/363G VLS4{404} | VLS4{659}
VLS4{410} attr Seven Sisters Time coincidence (time on roll - compare with realtime) FUDGE ( ( SYSTEM{systime} > VLS4{regOTIME} ) & !VLS4{116} ) | VLS4_OVERRIDE_TIME_COINC
VLS4{571} attr Seven Sisters HS45611/362H VLS4{561} | ( VLS4{571} & VL6G ) | ( VLS4{571} & !RE )
VLS4{584} attr Seven Sisters HS45611/363G VL_584 | ( !VLS4{571} & VLS4{558} & !VL_583 ) | ( !VL_583 & VLS4{563} )
VLS4{621} attr Seven Sisters HS45611/363G VLS4{613} | VLS4{614}
VLS4{625} attr Seven Sisters Inter-sequence machine route permission HS45611/364F !VLS3{674} & ( ( 468E & VL24{673} & VLP5{645} ) | ( VLP5{645} & VL24{N} & !VL24U_PMCALL & !VLS3{211} ) | VLS3{673} ) & VL38F5
VLS4{625} attr Seven Sisters Inter-sequence machine route permission HS45611/364F !VLS3{674} & VL38F3 & VL38F5
VL38F3 relay Seven Sisters HS45611/364F ( 468E & VL24{673} & VLP5{645} ) | ( VLP5{645} & VL24{N} & !VL24U_PMCALL & !VLS3{211} ) | VLS3{673}
VL38F5 relay Seven Sisters HS45611/364F VL7G | 468E | !( TH & TJ )
VLS4{659} attr Seven Sisters HS45611/363G ( VLS4{211} & !453B ) | ( VLS4{659} & !VLS4{661} & VLS4{1001} )
VLS4{661} attr Seven Sisters HS45611/363G ( VLS4{661} & VL13{R} ) | ( !VL22{N} & !SU & VL13{R} ) | ( VLS4{661} & !VLS4{124} & RF & RG )
VLS4{679} attr Seven Sisters CALL VL7U (TD Code Readout route 2) HS45611/364F ( !TC & VL8G ) | ( RJ & VL7{N} & VLS4{679} ) | ( RL & VL20{N} & VLS4{679} ) | ( VL12{N} & VL13{N} & VL6G & RE & !RD & VLS4{1002} ) | ( RE & VLS4{661} & VL12{N} & VL13{N} & VL6G )
VL39A6 relay Seven Sisters HS45611/364F ( VLS4{682} & VLS4{361} ) | ( VLS4{682} & VLS4{366} ) | ( !VLS4{694} & VLS4{584} & !VLS4{116} & !VLS4{693} & VLS4{621} & VLS4{319} )
VLS39A7_5 relay Seven Sisters HS45611/364F ( VL20{N} | RJ ) & VLS4{680} & RL
VLS4{680} attr Seven Sisters HS45611/364F ( !RD & VL39A6 & VL6G & VL12{N} & VL13{N} ) | VLS39A7_5
VLS4{1001} attr Seven Sisters HS45611/363G !VLS4{YUPR} & !VLS4{526} & !VLS4{571} & !VLS4{562} & !VLS4{584} & !VLS4{124}
VLS4{1002} attr Seven Sisters HS45611/364F ( VLS4{366} & VLS4{681} ) | ( VLS4{681} & VLS4{361} ) | ( VLS4{674} & VLS4{361} ) | ( VLS4{674} & VLS4{366} ) | ( VLS4{693} & VLS4{584} ) | ( VLS4{694} & VLS4{584} )
VLS4{211} attr Seven Sisters HS45611/364F ( QA & VLS4{1001} & VLS4{211} ) | ( VLS4{1001} & QA & QB & QC & QD & QE & RA & RB & RC & RD & !VLS2{YUPR} & VL39H2 & ( VLS2{640} | !( 449A & 449B ) ) & VLS2{571} & VL39H1 & VL13{N} & VLS4{410} & VL1{N} & VL39H3 )
VL39H2 relay Seven Sisters HS45611/364F ( VLS2{612} & !VLS2{226} & VLS2{319} & VL39G1 ) | ( VL39G1 & VLS2{366} )
VL39G1 relay Seven Sisters HS45611/364F VLS2{674} | VLS2{675} | VLS2{584}
VL39H1 relay Seven Sisters HS45611/364F ( VL23{N} & ST & 464A ) | !VL22{N} | VL22_1U_PMCALL
VL39H3 relay Seven Sisters HS45611/364F ( !VLS4{225} & VLS4{611} & VLS4{319} ) | ( !VLS4{226} & VLS4{612} & VLS4{319} )
VLS4{YUPR} attr Seven Sisters FROM REGULATOR - PB HS45611/363G VL_YU_MASTER & VLS4_REG_PB & !VL_582
VLS4{534} attr Seven Sisters FROM REGULATOR - Extra Train HS45611/363G VLS4_REG_EXT_TRAIN & !VL_582
VLS4{536} attr Seven Sisters FROM REGULATOR - Train cancel HS45611/363G VLS4_REG_TRAIN_CANCEL
VLS4{529} attr Seven Sisters FROM REGULATOR - Immediate extra train HS45611/363G VLS4_REG_IMMED_EXT_TRAIN
VLS4{563} attr Seven Sisters FROM REGULATOR - PM Ackknowledge HS45611/363G ( VLS4_REG_PM_ACK | VLS4{563} ) & VLS4{566}
VLS4{558} attr Seven Sisters FROM REGULATOR - PM Only HS45611/363G VLS4_REG_PM_ONLY
VLS4{562} attr Seven Sisters FROM REGULATOR - FCFS HS45611/363G ( !VL_582 & VLS4_REG_FCFS ) | VL_583
VLNB{475} attr Seven Sisters FROM REGULATOR - NB Engineers Test HS45611/363G VLNB_REG_ENG_TRAIN
VLS4{526} attr Seven Sisters FROM REGULATOR - No out of turn HS45611/363G ( VLS4_REG_NOOT | VLS4{526} ) & VLS4{520}
VLS4{566} attr Seven Sisters TO REGULATOR - Out Of Agreement & PM Ack Stick HS45611/363G VLS4{366} & RE & !VLS4{584} & !VLS4{361} & VL39C13 & VL39C11 & VLS3{319}
VL39C13 relay Seven Sisters ^^^^ HS45611/363G VLS4{681} & VLS4{682} & VLS4{673} & VLS4{674}
VL39C11 relay Seven Sisters ^^^^ HS45611/363G ( !VLS4{225} & VLS4{611} ) | ( !VLS4{226} & VLS4{612} ) | ( !VLS4{226} & VLS4{613} ) | ( !VLS4{226} & VLS4{614} )
VLS4{569} attr Seven Sisters 567-569? TO REGULATOR - Storage HS45611/363G VLS4{225} | VLS4{226}
VLS4{520} attr Seven Sisters TO REGULATOR - Train OOT & NOOT stick HS45611/363G VLS4{211} | VLS4{424} | ( VLS4{526} & QA )
VLS4{546} attr Seven Sisters TO REGULATOR - Train Cancel HS45611/363G VLS4{328}
VLS4{561} attr Seven Sisters TO REGULATOR - Extra Train See 358 HS45611/362H ( !VLS4{124} & !VL6G & VLS4{561} ) | ( VLS4{330} & VLS4{113} & VLS4{534} ) | ( !VLS4{124} & RE & VLS4{561} ) | ( VLS4{534} & VLS4{529} & ( RE | VL6{N} ) )
VLS4{PM225store:VLS4{regTN}} attr Seven Sisters HS45611/352E VL6G & !VL6{N} & VL12{N} & !VLS4{571} & !RE & VLS4{611}
VLS4{PM226store:VLS4{regTN}} attr Seven Sisters HS45611/352E VLS4{661} & VL6G & VL12{R} & !VL6{N} & !VLS4{571} & !RE & ( VLS4{612} | VLS4{613} | VLS4{614} )
VLS4{PM225storecanc} attr Seven Sisters HS45611/352E VLS4{113} & VLS4{226} & VLS4{332} & ( VLS4{612} | VLS4{613} | VLS4{614} )
VLS4{PM226storecanc} attr Seven Sisters HS45611/352E VLS4{113} & VLS4{225} & VLS4{332} & VLS4{611} & ( VLNB{475} | ( !VLNB{475} & !VLS4{377} ) )
VLS6{mode} attr PM mode return "PB" if VLS6{YUPR} eq "1"; return "FCFS" if VLS6{562} eq "1"; return "PMonly" if VLS6{558} eq "1"; return "PM";
VLS6{311} attr TN non zero VLS6{extcantrn} != 0
VLS6{330} attr TN Coincidence ( VLS6{regTN} eq VLS6{extcantrn} ) & !VL_582
VLS6{332} attr TN Non-Coincidence !( VLS6{regTN} eq VLS6{extcantrn} ) | ( !VLS6{116} & VL_582 )
VLS6{361} attr TD Coincidence - not on S6 VLS6{TD} eq VLS6{regTD}
VLS6{377} attr Special PM Roll hole 17 VLS6{regHOLE17}
VLS6{step} attr Seven Sisters Step HS45611/365G VLS6_MAN_STEP | ( VLS2{124} & VLS6{410} & VLS6{124} ) | ( VLS6{536} & VLS6{330} & !VLS6{124} & !VLS6{328} ) | VL40G18_4 | VL40G18_5 | VL40G19
VL40G18_4 relay Seven Sisters HS45611/365G VLS6{332} & ( ( VLS6{611} & VLS6{221} ) | ( VLS6{612} & VLS6{222} ) )
VL40G18_5 relay Seven Sisters HS45611/365G !VLNB{475} & VLS6{377}
VL40G19 relay Seven Sisters HS45611/365G ( ( !455C & !VL4G & !455D & !VLS6{221} ) | ( !VL6G & !RE & !VLS6{222} & VL12{R} & !RD ) ) & !VLS6{571} & !VLS6{124} & !VLS6{122} & !VLS6{131}
VLS6{131} attr Seven Sisters HS45611/365G ( !455D & VLS6{116} ) | ( !RE & VLS6{116} & VL12{R} ) | ( VLS6{131} & !455D ) | ( VLS6{131} & !RE & VL12{R} )
VLS6{132} attr Seven Sisters HS45611/365G ( RE & 455D ) | ( VL12{R} & RE ) | ( VL12{N} & 455D )
VLS6{149} attr Next train out plat 3 Not VPP3{149}? HS46965/42 VLS6{611} Page missing - permanent SET to whatever S6/611 says
VLS6{151} attr Next train out plat 4 Not VPP4{151}? HS46965/42 VLS6{612} Page missing - permanent SET to whatever S6/612 says
VLS6{211} attr Seven Sisters Permission to run out of turn 1 request HS45611/367C ( VLS6{211} & VLS6{1001} & 455E ) | ( VLS6{612} & !VLS6{222} & VLS6{1001} & VLS6{410} & VLP3{632} & VLS6{319} & VL40E19 & VL40E20 & VL4{N} )
VL40E19 relay Seven Sisters 366 inv? HS45611/367C VLS4{YUPR} | !VLS4{414} | ( VLS4{361} & VLS4{674} ) | ( VLS4{674} & VLS4{366} )
VL40E20 relay Seven Sisters HS45611/367C VL6{N} | VL12{N}
VLS6{212} attr Seven Sisters Permission to run out of turn 2 request HS45611/367C ( VLS6{212} & VLS6{1001} & RF ) | ( VLS6{611} & !VLS6{221} & VLS6{319} & VLS6{410} & VL40A10 & VLS6{1001} & VL4{N} & VLS4{414} & !VLS4{YUPR} & VL40A7 & VL6{N} & !VLP3{632} & !VLS4{124} & !VLS4{571} & QH & QJ & QG & QF )
VL40A7 relay Seven Sisters HS45611/367C ( !VLS4{225} & VLS4{319} & VLS4{673} & VLS4{361} ) | ( VLS4{673} & VLS4{366} ) | ( VLS4{584} & VLS4{611} & !VLS4{225} & VLS4{319} )
VL40A10 relay Seven Sisters HS45611/367C ( 453B & QA ) | VL10{R}
VL_TD_WARNING_BELL relay Seven Sisters HS45611/366H VLS6{YUPR} | VLS4{YUPR} | VL40C10 | VL40C11 | VLS6{562} | VLS4{562}
VL40C10 relay Seven Sisters HS45611/366H VLS6{611} & !VLS6{221} & !VLS6{116} & !VLS6{124} & VLS6{319} & !VLS6{113}
VL40C11 relay Seven Sisters HS45611/366H !VLS6{124} & VLS6{319} & !VLS6{113} & VLS6{612} & !VLS6{222} & !VLS6{116}
VLS6{319} attr Seven Sisters Train cancel guard HS45611/365G ( VLS6{629} & VLS6{534} ) | ( VLS6{629} & VLS6{332} )
VLS6{328} attr Seven Sisters Train cancel coincidence stick relay HS45611/365G ( VLS6{113} & VLS6{330} & VLS6{536} ) | ( VLS6{328} & VLS6{536} ) | ( VLS6{311} | VLS6{328} )
VLS6_404_JR relay Seven Sisters 60 HS45611/367C VLS6{211} | VLS6{212}
VLS6{404} attr Seven Sisters Time Delay unit - 1m HS45611/367C VLS6_404_JR
VLS6{410} attr Seven Sisters Time coincidence (time on roll - compare with realtime) FUDGE ( ( SYSTEM{systime} > VLS6{regOTIME} ) & !VLS6{116} ) | VLS6_OVERRIDE_TIME_COINC
VLS6{424} attr Seven Sisters Route Selection Control Delay relay HS45611/367C VLS6{404} | VLS6{660} | VLS6{659}
VLS6{571} attr Seven Sisters Extra train guard relay HS45611/365G VLS6{561} | ( VLS6{571} & !455D ) | ( VLS6{571} & VL4G ) | ( VLS6{571} & !RE ) | ( VLS6{571} & VL6G )
VLS6{629} attr Seven Sisters Special guard relay HS45611/367C ( !VLS6{113} & !VLS6{116} & VLNB{475} ) | ( !VLS6{113} & !VLS6{116} & !VLS6{377} )
VLS6{659} attr Seven Sisters Train Out Of Turn (trailing route 1) HS45611/367C ( !455D & VLS6{211} & VL4G & VLS6{424} ) | ( VLS6{659} & VLS6{1001} & ( RE | VL12{N} ) )
VLS6{660} attr Seven Sisters Train Out Of Turn (trailing route 2) HS45611/367C ( VLS6{212} & VL6G & VL12{R} & !RE & VLS6{424} ) | ( VLS6{660} & 455D & VLS6{1001} )
VLS6{1001} attr Seven Sisters HS45611/367C !VLS6{YUPR} & !VLS6{562} & !VLS6{571} & !VLS6{526} & !VLS6{124} & !VL_582
VLS6{562} attr Seven Sisters FROM REGULATOR - FCFS HS45611/366H ( !VL_582 & VLS6_REG_FCFS ) | VL_583
VLS6{YUPR} attr Seven Sisters FROM REGULATOR - PB HS45611/366H VL_YU_MASTER & VLS6_REG_PB & !VL_582
VLS6{534} attr Seven Sisters FROM REGULATOR - Extra Train HS45611/366H VLS6_REG_EXT_TRAIN & !VL_582
VLS6{526} attr Seven Sisters FROM REGULATOR - No out of turn HS45611/366H ( VLS6_REG_NOOT | VLS6{526} ) & VLS6{520}
VLS6{529} attr Seven Sisters FROM REGULATOR - Immediate extra train HS45611/366H VLS6_REG_IMMED_EXT_TRAIN
VLS6{536} attr Seven Sisters FROM REGULATOR - Train cancel HS45611/366H VLS6_REG_TRAIN_CANCEL
VLS6{541} attr TD 541 FROM REGULATOR - Plat 3 setup CS46965/42C VLS6_REG_PLAT3_SETUP
VLS6{542} attr TD 542 FROM REGULATOR - Plat 4 setup CS46965/42C VLS6_REG_PLAT4_SETUP
VLS6{551} attr TD 551 FROM REGULATOR - Plat number cancel CS46965/42C VLS6_REG_PLAT_CANCEL  | ( VLS6{520} & !VLS6{424} ) Umm, added {520} to cancel.  This is a fudge
VLS6{143} attr TD 143 TD Platform cancel repeater CS46965/42C VLS6{551} | ( VLS6{143} & !VLS6{149} & !VLS6{151} ) was: VLS6{551} | ( VLS6{143} & VLS6{1002} & !VLS6{124} )
VLS6{549} attr TD 549 CS46965/42C VLS6{143} | ( VLS6{549} & !VLS6{732} ) | ( !VLP3{141} & !VLP4{141} & VLS6{580} & !VLS6{113} )
VLS6{732} attr TD 732 via 37AV14 CS46965/42C VL_CANCEL_SIGN_TO_TD
VLP3{141} attr P3/141 via 37AV9/VL40H3 CS46965/42C VL_PLAT3_ARROW_SETUP
VLP4{141} attr P4/141 via 37AV10/VL40H6 CS46965/42C VL_PLAT4_ARROW_SETUP
VL_TD_WARNING_BELL_JR relay via 37AV11/VL40C9 2 CS46965/42C VL_TD_WARNING_BELL
VLS6{580} attr TD 580 WARNING BELL CS46965/42C VL_TD_WARNING_BELL_JR
VLS6{149} attr TD 149 TO REGULATOR - Plat3 Arrow & KE CS46965/42C ( !VLS6{549} & VLP3{141} & !VLS6{143} & !VLS6{151} ) | ( !VLS6{151} & VLS6{541} ) | ( VLS6{149} & !VLS6{143} & VLS6{549} & !VLS6{732} ) was: ( !VLS6{151} & VLS6{142} ) | ( !VLS6{143} & VLS6{319} & !VLS6{151} & ( VLP3{1001} | ( !VLP4{1001} & VLS6{611} & !VLS6{116} ) ) )
VLS6{151} attr TD 151 TO REGULATOR - Plat4 Arrow & KE CS46965/42C ( !VLS6{549} & VLP4{141} & !VLS6{143} & !VLS6{149} ) | ( VLS6{542} & !VLS6{149} ) | ( VLS6{151} & !VLS6{143} & VLS6{549} & !VLS6{732} ) was: ( !VLS6{149} & VLS6{141} ) | ( !VLS6{143} & VLS6{319} & !VLS6{149} & ( VLP4{1001} | ( !VLP3{1001} & VLS6{612} & !VLS6{116} ) ) )
VL_CHECK_ARROW relay TO REGULATOR - Check Arrow CS46965/42C !VLS6{143} & !VLS6{149} & !VLS6{151} & VLS6{580}
VLP3{632} attr Seven Sisters HS45611/367C ( !455A | !455B | !455C ) & 455D
VL_PLAT3_ARROW_SETUP relay HS45611/366H ( !VLS6{562} & VL40H2 ) | ( VLS6{211} & VLS6{424} )
VL40H2 relay HS45611/366H ( ( VLS6{319} & VLS6{611} & !VLS6{YUPR} ) | ( VLS6{319} & VLS6{613} & !VLS6{YUPR} ) ) & !VLS6{221} & ( !VLS6{212} | ( VLS6{319} & VLS4{377} ) )
VL_PLAT4_ARROW_SETUP relay HS45611/366H ( !VLS6{562} & !VLS4{562} & !VLS6{YUPR} & !VLS4{YUPR} & VL40H4_3 ) | ( !VLS4{377} & VLS6{212} & VLS6{424} )
VL40H4_3 relay HS45611/366H ( ( !VLS6{377} & VLS6{612} & VLS6{319} ) | ( VLS6{614} & VLS6{319} ) ) & !VLS6{222} & !VLS6{211}
VL_CANCEL_SIGN_TO_TD relay HS45611/366H ( !VLS6{132} & VL4G ) | ( !VLS6{132} & VL6G )
VLP3_ARROW_PLAT_R relay Fed from 46965/42C CS46965/41G VLS6{149}
VLP4_ARROW_PLAT_R relay Fed from 46965/42C CS46965/41G VLS6{151}
VLS6{567} attr Seven Sisters 567-569? TO REGULATOR - Storage HS45611/366H VLS6{221} | VLS6{222}
VLS6{546} attr Seven Sisters TO REGULATOR - Train Cancel HS45611/366H VLS6{328}
VLS6{561} attr Seven Sisters TO REGULATOR - Extra Train See 358 HS45611/365G !VLS6{124} & ( ( VLS6{529} & VLS6{534} & VLS6{132} ) | ( VLS6{534} & VLS6{113} & VLS6{303} ) | ( VLS6{561} & VLS6{132} ) | ( VLS6{561} & !VL4G & ( RE | VL12{N} ) ) | ( VLS6{561} & !VL6G & 455D ) )
VLS6{520} attr Seven Sisters TO REGULATOR - Train OOT & NOOT stick HS45611/366H VLS6{211} | VLS6{212} | VLS6{424} | ( !VLS6{124} & VLS6{526} & 455D ) | ( !VLS6{124} & !RE & VLS6{526} & VL12{R} )
VLS6{TD} attr return "BCD" if VLS6{ID} eq "1"; return "ACD" if VLS6{ID} eq "2"; return "ABC" if VLS6{ID} eq "3"; return "C" if VLS6{ID} eq "4"; return "D" if VLS6{ID} eq "5"; return "B" if VLS6{ID} eq "6"; return "A" if VLS6{ID} eq "7"; return "ABD" if VLS6{ID} eq "8"; return "";
VLS6{PM221store:VLS6{regTN}} attr Seven Sisters HS45611/352E !455D & !VLS6{571} & VLS6{612} & VL4G
VLS6{PM222store:VLS6{regTN}} attr Seven Sisters HS45611/352E !VLS6{571} & VLS6{611} & VL6G & VL12{R} & !RE
VLS6{PM221storecanc} attr Seven Sisters HS45611/352E VLS6{113} & VLS6{221} & VLS6{332} & VLS6{611}
VLS6{PM222storecanc} attr Seven Sisters HS45611/352E VLS6{113} & VLS6{222} & VLS6{332} & VLS6{612}
SEVEN SISTERS MAG AMPS
VL1_1U_RUMIN relay Seven Sisters HS45611/376 ( pbVL1_1{PUSH} & VLS2{YUPR} ) | ( VL1_1U_PMCALL & !VLS2{YUPR} )
VL1_1U_NUMIN relay Seven Sisters HS45611/376 ( pbVL1_1{PULL} & VLS2{YUPR} ) | ( !453B & VL1G )
VL1_1U_RUM relay Seven Sisters HS45611/376 VL1_1U_RUMIN | ( VL1_1U_RUM & !VL1_1U_NUMIN )
VL37B11 relay Seven Sisters HS45611/356G ( ( !VLS2{584} & VLS2{361} ) | VLS2{584} ) & !VLS2{YUPR} & 453B & VLS2{640} & VLS2{319} & !VLS2{366} & !VLS2{571}
VL1_1U_PMCALL relay HS45611/356G ( VL37B11 & VLS2{611} & !VLS2{225} ) | ( 453B & VLS2{640} & VLS2{673} & VLS2{366} )
VL1_2U_RUMIN relay Seven Sisters HS45611/377 ( pbVL1_2{PUSH} & VLS2{YUPR} ) | ( VL1_2U_PMCALL & !VLS2{YUPR} )
VL1_2U_NUMIN relay Seven Sisters HS45611/377 ( pbVL1_2{PULL} & VLS2{YUPR} ) | ( !453B & VL1G )
VL1_2U_RUM relay Seven Sisters HS45611/377 VL1_2U_RUMIN | ( VL1_2U_RUM & !VL1_2U_NUMIN )
VL37B12 relay Seven Sisters HS45611/356G VLS4{562} | ( !VLS4{226} & VLS4{613} & VLS4{319} ) | ( VLS4{319} & VLS4{614} & !VLS4{226} ) | ( VLS4{424} & VLS4{211} )
VL37B13 relay Seven Sisters HS45611/356G VLS2{674} | VLS2{675}
VL1_2U_PMCALL relay Seven Sisters HS45611/356G ( VL37B11 & VL37B12 & VLS2{612} & !VLS2{226} ) | ( VL37B12 & VL37B13 & VLS2{366} & VLS2{640} & 453B )
VL2U_RUMIN relay Seven Sisters HS45611/378 VL1{R} & !453A & 455C & VL10{N} & VL12{N} & !VL6_1U_RUM
VL2U_NUMIN relay Seven Sisters HS45611/378 ( QG & QH & QJ & 455A & 453B & QA & QF & 455B & VL1{N} ) | !455C
VL2U_RUM relay Seven Sisters HS45611/378 VL2U_RUMIN | ( VL2U_RUM & !VL2U_NUMIN )
VL4U_RUMIN relay Seven Sisters See SHT 367 HS45611/379 ( pbVL4{PUSH} & VLS6{YUPR} ) | VL4U_PMCALL
VL4U_NUMIN relay Seven Sisters HS45611/379 ( pbVL4{PULL} & VLS6{YUPR} ) | ( !455D & VL4G )
VL4U_RUM relay Seven Sisters HS45611/379 VL4U_RUMIN | ( VL4U_RUM & !VL4U_NUMIN )
VL4U_PMCALL relay Seven Sisters Added tracks to avoid race condition. Cancels call if both are down HS45611/367C ( ( 455B | 455D ) & VLS6{211} & VLS6{424} & VLS6{149} ) | ( VLP3{632} & VL40J8 & VLS6{149} & !VLS6{YUPR} & !VLS6{571} & VL40J7 & !VL4G )
VL40J7 relay Seven Sisters HS45611/367C VL6{N} | VL12{N}
VL40J8 relay Seven Sisters HS45611/367C ( VLS6{410} & VLS6{611} & !VLS6{221} & VLS6{319} ) | VLS6{562}
VL5U_RUMIN relay Seven Sisters HS45611/380 ( !QC | !QA | !451A | !451B | !451C | !453A | !453B | !QB | !QD | !QE | !QF | !RA | !RB | !RC ) & VL10{R} & RD
VL5U_NUMIN relay Seven Sisters HS45611/380 !RD | ( 453B & QA & QB & QC & QD & QE & RA & RB & RC & VL1{N} )
VL5U_RUM relay Seven Sisters HS45611/380 VL5U_RUMIN | ( VL5U_RUM & !VL5U_NUMIN )
VL6_1U_RUMIN relay Seven Sisters See SHT 364 HS45611/381 ( pbVL6_1{PUSH} & VLS4{YUPR} ) | VL6_1U_PMCALL
VL6_1U_NUMIN relay Seven Sisters HS45611/381 ( pbVL6_1{PULL} & VLS4{YUPR} ) | ( !RE & VL6G )
VL6_1U_RUM relay Seven Sisters HS45611/381 VL6_1U_RUMIN | ( VL6_1U_RUM & !VL6_1U_NUMIN )
VL6_1U_PMCALL relay Seven Sisters Not in PB, 2min layover, plus the below HS45611/364P !VLS4{YUPR} & !VLS6{YUPR} & VL38B15 & VL38B13 & VL38B12 & VLS4{414}
VL38B15 relay Seven Sisters Plat 4 out next, plus special service on roll HS45611/364P VLS6{151} | VLS4{377}
VL38B12 relay Seven Sisters S6{612} (plat4) and time coinc(410) and not storage OR OOT OR FCFS HS45611/364P ( VLS6{410} & VLS6{612} & !VLS6{222} & VLS6{319} ) | ( VLS6{212} & VLS6{424} ) | VLS6{562}
VL38B13 relay Seven Sisters HS45611/364P ( VLS4{366} & VLS4{673} ) | ( VLS4{611} & VLS4{319} & !VLS4{225} & VL38B7 )
VL38B7 relay Seven Sisters Not extra train, not train cancel not PB  HS45611/364P VL38B5 & !VLS4{366} & !VLS4{YUPR} & VLS4{319} & VL38B6 & !VLS4{571}
VL38B5 relay Seven Sisters PM only, or not PM only and TD coincidence HS45611/364P VLS4{584} | ( !VLS4{584} & VLS4{361} )
VL38B6 relay Seven Sisters Train in platform 4 HS45611/364P ( !RB & RE ) | ( RE & !RC ) | ( RE & !RD )
VL6_2U_RUMIN relay Seven Sisters HS45611/382 ( pbVL6_2{PUSH} & VLS4{YUPR} ) | ( VL6_2U_PMCALL & !VLS4{YUPR} )
VL6_2U_NUMIN relay Seven Sisters HS45611/382 ( pbVL6_2{PULL} & VLS4{YUPR} ) | ( !RE & VL6G )
VL6_2U_RUM relay Seven Sisters HS45611/382 VL6_2U_RUMIN | ( VL6_2U_RUM & !VL6_2U_NUMIN )
VL6_2U_PMCALL relay Seven Sisters HS45611/382 VL14{N} & VL38B19 & !VL20U_PMCALL & !VL8U_PMCALL & RG & RJ & RK & RL & VLS4{625}
VL38B19 relay Seven Sisters Mistake in 612 & 226? HS45611/364P ( VLS4{613} & VL38B7 & !VLS4{226} & VL38E12 ) | ( VL38E10 & VL38E14 & VLS4{366} & VLS4{674} & VL38B6 ) | ( VL38B6 & VLS4{366} & VL38D19 ) | ( VLS4{612} & !VLS4{226} & VLS4{319} & VLS4{414} & VLS4{410} & VL38B7 )
VL38E10 relay Seven Sisters HS45611/364P !VLS4{661} | VLS4{414}
VL38E12 relay Seven Sisters HS45611/364P !VLS4{693} | ( VLS4{693} & VLS4{410} )
VL38E14 relay Seven Sisters HS45611/364P VLS4{562} | VLS4{410}
VL38D19 relay Seven Sisters HS45611/364P ( VLS4{682} & !VL6_3U_PMCALL ) | VLS4{681}
VL6_3U_RUMIN relay Seven Sisters HS45611/383 ( pbVL6_3{PUSH} & VLS4{YUPR} ) | ( VL6_3U_PMCALL & !VLS4{YUPR} )
VL6_3U_NUMIN relay Seven Sisters HS45611/383 ( pbVL6_3{PULL} & VLS4{YUPR} ) | ( !RE & VL6G )
VL6_3U_RUM relay Seven Sisters HS45611/383 VL6_3U_RUMIN | ( VL6_3U_RUM & !VL6_3U_NUMIN )
VL6_3U_PMCALL relay Seven Sisters HS45611/383 VL14{N} & VL38A15 & !VL20U_PMCALL & !VL8U_PMCALL & RG & RH & SU & ST & SP & VLS1{613} & !VLS1{224} & VLS1{319} & RJ & VL23{N}
VL38A15 relay Seven Sisters HS45611/364P ( VLS4{614} & VL38B7 & !VLS4{226} ) | ( VL38B6 & VLS4{682} & ( !RL | !RK ) & VLS4{366} )
VL7U_RUMIN relay Seven Sisters See SHT 364 HS45611/384 ( pbVL7{PUSH} & VLS4{YUPR} ) | VL7U_PMCALL
VL7U_NUMIN relay Seven Sisters HS45611/384 ( pbVL7{PULL} & VLS4{YUPR} ) | ( !RL & VL7G )
VL7U_RUM relay Seven Sisters HS45611/384 VL7U_RUMIN | ( VL7U_RUM & !VL7U_NUMIN )
VL7U_PMCALL relay Seven Sisters HS45611/364P !VLS4{YUPR} & VLS4{679}
VL8U_RUMIN relay Seven Sisters HS45611/385 ( pbVL8{PUSH} & VLS3{YUPR} ) | ( VL8U_PMCALL & !VLS3{YUPR} ) | VL8U_SPECIAL_CALL
VL8U_NUMIN relay Seven Sisters HS45611/385 ( pbVL8{PULL} & VLS3{YUPR} ) | ( !TC & VL8G )
VL8U_RUM relay Seven Sisters HS45611/385 VL8U_RUMIN | ( VL8U_RUM & !VL8U_NUMIN )
VL32E11 relay Seven Sisters HS45611/360J ( ( !VLS3{584} & VLS3{361} ) | ( TH & TJ & VLS3{584} ) )
VL32E17 relay Seven Sisters HS45611/360J VL32E11 & !VLS3{562} & !VLS3{366} & !VLS3{561} & VL24{633} & VLS3{614} & !VLS3{225} & VLS3{319}
VL32D18 relay Seven Sisters HS45611/360J VL32E17 | ( VL24{633} & VLS3{674} & VLS3{562} ) | ( VL24{633} & VLS3{674} & VLS3{366} )
VL8U_PMCALL relay Seven Sisters HS45611/360J ( VLS3{212} & VLS3{674} ) | ( !VLP5{645} & VL32D18 & TC & !VLS3{212} & !VL18U_PMCALL & !VLS3{YUPR} & !VL24U_PMCALL & !VL6_2U_PMCALL & !VL6_3U_PMCALL & RL & RK & !VL22_1U_PMCALL & !VL22_2U_PMCALL & VLS3{1206} & VL20{N} & VL24{N} & VL22{N} )
VL18U_RUMIN relay Seven Sisters HS45611/386 ( pbVL18{PUSH} & VLS3{YUPR} ) | ( VL18U_PMCALL & !VLS3{YUPR} )
VL18U_NUMIN relay Seven Sisters HS45611/386 ( pbVL18{PULL} & VLS3{YUPR} ) | ( !( TH & TJ ) & VL18G )
VL18U_RUM relay Seven Sisters HS45611/386 VL18U_RUMIN | ( VL18U_RUM & !VL18U_NUMIN )
VL18U_PMCALL relay Seven Sisters HS45611/360J ( !VLP5{645} & VL32D12 & TH & TJ & VL8{N} & !VLS3{YUPR} ) | ( VLS3{212} & VLS3{673} )
VL32D12 relay Seven Sisters HS45611/360J VL32D6 | ( VLS3{562} & VLS3{673} ) | ( VLS3{673} & VLS3{410} & VLS3{366} )
VL32D6 relay Seven Sisters HS45611/360J !VLS3{561} & !VLS3{562} & !VLS3{366} & VLS3{410} & VL32D10 & VL32D11
VL32D10 relay Seven Sisters HS45611/360J ( !VLS3{211} & VLS3{611} & VL24{633} ) | ( VLS3{612} & !VLS3{222} & VL32D17 ) | ( VL32D16 & !VLS3{220} & VLS3{613} )
VL32D17 relay Seven Sisters HS45611/360J ( !VLS3{161} & VL22{633} ) | ( VL20{633} & VLS3{160} )
VL32D16 relay Seven Sisters Fixed typo in schematic VLS1{161} HS45611/360J ( !VLS3{160} & VL20{633} ) | ( VL22{633} & VLS3{161} )
VL32D11 relay Seven Sisters HS45611/360J ( ( !VLS3{584} & VLS3{361} & VLS3{319} ) | ( VLS3{319} & VLS3{584} ) )
VL19U_RUMIN relay Seven Sisters See SHT 353 HS45611/387 ( pbVL19{PUSH} & ( VLS1{YUPR} | VLS3{YUPR} ) ) | VL19U_PMCALL
VL19U_NUMIN relay Seven Sisters HS45611/387 ( pbVL19{PULL} & ( VLS1{YUPR} | VLS3{YUPR} ) ) | ( !TC & VL19G )
VL19U_RUM relay Seven Sisters HS45611/387 VL19U_RUMIN | ( VL19U_RUM & !VL19U_NUMIN )
VL19U_PMCALL relay Seven Sisters HS45611/353 TC & !VLS3{YUPR} & ( ( !RJ & VL14{R} & !VL20{N} ) | ( !SU & VL13{N} & !VL22{N} ) )
VL20U_RUMIN relay Seven Sisters HS45611/388 ( pbVL20{PUSH} & VLS3{YUPR} ) | ( VL20U_PMCALL & !VLS3{YUPR} ) | VL20U_SPECIAL_CALL
VL20U_NUMIN relay Seven Sisters HS45611/388 ( pbVL20{PULL} & VLS3{YUPR} ) | ( !RJ & VL20G )
VL20U_RUM relay Seven Sisters HS45611/388 VL20U_RUMIN | ( VL20U_RUM & !VL20U_NUMIN )
VL32B2 relay Seven Sisters HS45611/360J VLS3{319} & VLS3{613} & !VLS3{220} & !VLS1{605} & !VLS1{662}
VL32B3 relay Seven Sisters HS45611/360J VLS3{612} & !VLS3{222} & VLS3{319} & !VLS1{661} & VLS1{605} & !VLS1{640}
VLS32B4 relay Seven Sisters HS45611/360J VL32B2 | VL32B3 | ( VLS4{680} & VLS3{562} & !VLS1{562} )
VL20U_PMCALL relay Seven Sisters HS45611/360J VLS3{431} & !VLS3{211} & !VL22_1U_PMCALL & !VL22_2U_PMCALL & !VL24U_PMCALL & !VL6_3U_PMCALL & !VLS3{YUPR} & VLS3{1206} & VL22{N} & RJ & VL8{N} & VL24{N} & !VL24U_PMCALL & VLS3{1002} & !VLS3{212} & VLS32B4
VL21U_RUMIN relay Seven Sisters HS45611/389D VL22_2U_RUM
VL21U_NUMIN relay Seven Sisters HS45611/389D ( VL13{N} & !RD ) | ( VL13{N} & SU )
VL21U_RUM relay Seven Sisters HS45611/389D VL21U_RUMIN | ( VL21U_RUM & !VL21U_NUMIN )
VL22_1U_RUMIN relay Seven Sisters HS45611/390 ( pbVL22_1{PUSH} & VLS1{YUPR} ) | ( VL22_1U_PMCALL & !VLS1{YUPR} ) | VL22_1U_SPECIAL_CALL
VL22_1U_NUMIN relay Seven Sisters HS45611/390 ( pbVL22_1{PULL} & VLS1{YUPR} ) | ( !SU & VL22BG )
VL22_1U_RUM relay Seven Sisters HS45611/390 VL22_1U_RUMIN | ( VL22_1U_RUM & !VL22_1U_NUMIN )
VL22_1U_PMCALL relay Seven Sisters HS45611/353 !VLS1{YUPR} & !VL22_2U_PMCALL & !VL8U_PMCALL & !VLS3{211} & !VL20U_PMCALL & !VL6_3U_PMCALL & !VLS3{YUPR} & SU & 468E & VLS3{1002} & VL14{N} & VL32F15 & !VL24U_PMCALL & VL8{N} & VL24{N} & TE & TC & SV & VLP5{645}
VL32A18 relay Seven Sisters HS45611/353 VLS1{562} & VLS3{562} & !VLS1{640} & VLS1{431}
VL32F8 relay Seven Sisters HS45611/353 VLS3{319} & VLS3{220} & VLS3{613} & VLS1{662} & VLS1{606} & VLS1{431}
VL32F15 relay Seven Sisters HS45611/353 VL32F8 | VL32A18 | VL32F12_4
VL32F12_4 relay Seven Sisters HS45611/353 !VLS1{606} & VL32A20 & VL32F17
VL32A20 relay Seven Sisters HS45611/353 ( VLS1{562} & VLS3{562} ) | ( ( !VLS1{661} | VLS1{640} ) & VLS3{612} & !VLS3{222} & VLS3{319} )
VL32F17 relay Seven Sisters HS45611/353 VL32F7 | VL32F20 | ( VLS1{640} & VLS1{673} & VLS1{562} )
VL32F20 relay Seven Sisters HS45611/353 VLS1{613} & !VLS1{224} & !VLS1{640} & VLS1{431} & VLS1{319}
VL32F7 relay Seven Sisters HS45611/353 VL32F16 & VLS1{611} & !VLS1{225} & VLS1{319} & VLS1{640}
VL32F16 relay Seven Sisters HS45611/353 ( !VLS1{561} & VLS1{584} ) | ( !VLS1{561} & !VLS1{584} & VLS1{361} )
VL22_2U_RUMIN relay Seven Sisters HS45611/391 ( pbVL22_2{PUSH} & VLS1{YUPR} ) | ( VL22_2U_PMCALL & !VLS1{YUPR} )
VL22_2U_NUMIN relay Seven Sisters HS45611/391 ( pbVL22_2{PULL} & VLS1{YUPR} ) | ( !SU & VL22BG )
VL22_2U_RUM relay Seven Sisters HS45611/391 VL22_2U_RUMIN | ( VL22_2U_RUM & !VL22_2U_NUMIN )
VL22_2U_PMCALL relay Seven Sisters HS45611/353 VL32E6 & VL32E7 & VL32F1 & VL32F2
VL32E6 relay Seven Sisters HS45611/353 !VLS1{YUPR} & !VL22_1U_PMCALL & !VL8U_PMCALL & !VL20U_PMCALL & VL6{N} & !VLS4{YUPR}
VL32E7 relay Seven Sisters HS45611/353 VL11{N} & VLS1{640} & !VLS4{211} & VL32E9 & VL17{N}
VL32F1 relay Seven Sisters HS45611/353 ( VLS4{611} | VLS4{612} ) & VLS4{319} & !VLS4{225} & RH & QD & QE & !VL1_2U_PMCALL
VL32F2 relay Seven Sisters HS45611/353 RA & RB & RC & RD & RE & RG
VL32E9 relay Seven Sisters HS45611/353 ( VLS1{562} & VLS1{674} ) | ( !VLS1{561} & VL32E8 & !VLS1{226} & VLS1{319} & VLS1{612} )
VL32E8 relay Seven Sisters HS45611/353 VLS1{584} | ( !VLS1{584} & VLS1{361} )
VL23U_RUMIN relay Seven Sisters HS45611/392 ( pbVL23{PUSH} & VLS1{YUPR} ) | VL23U_PMCALL | VL23U_SPECIAL_CALL
VL23U_NUMIN relay Seven Sisters HS45611/392 ( pbVL23{PULL} & VLS1{YUPR} ) | ( !464B & VL23G )
VL23U_RUM relay Seven Sisters HS45611/392 VL23U_RUMIN | ( VL23U_RUM & !VL23U_NUMIN )
VL23U_PMCALL relay Seven Sisters HS45611/353 ST & SP & 464B & !VLS1{YUPR} & SQ & !464A & ( ( VLS1{612} & !VLS1{226} & VLS1{319} ) | ( VLS1{319} & !VLS1{225} & VLS1{611} ) )
VL24U_RUMIN relay Seven Sisters HS45611/393 ( pbVL24{PUSH} & VLS3{YUPR} ) | ( VL24U_PMCALL & !VLS3{YUPR} )
VL24U_NUMIN relay Seven Sisters HS45611/393 ( pbVL24{PULL} & VLS3{YUPR} ) | ( !468E & VL24G )
VL24U_RUM relay Seven Sisters HS45611/393 VL24U_RUMIN | ( VL24U_RUM & !VL24U_NUMIN )
VL32C6 relay HS45611/360J VLS3{611} & !VLS3{221} & !VLS3{562} & VLS3{1002} & VLS3{319}
VL32C7 relay HS45611/360J VLS3{319} & VLS3{614} & !VLS3{225} & VLS3{1002} & !VLS3{562}
VL32C11 relay HS45611/360J VL32C6 | VL32C7 | ( VLS3{1002} & VLS3{562} )
VL32C10 relay HS45611/360J TC & !VLS3{113} & VL8{N} & ( VL13{R} | ( !VL22_1U_PMCALL & VL22{N} ) )
VL32C9 relay HS45611/360J VLS3{625} & !( 468D & 468C & 468B & 468A ) & 468E & !VLS3{YUPR} & VL32C11 & VL17{N}
VL24U_PMCALL relay HS45611/360J ( VL32C9 & VL32C10 ) | ( VLS3{211} & VLS3{424} & 468E & TC )
VL24U_PMCALL relay HS45611/360J ( ( VLS3{625} & !( 468D & 468C & 468B & 468A ) & 468E & !VLS3{YUPR} & VL32C11 & VL17{N} ) & VL32C10 ) | ( VLS3{211} & VLS3{424} & 468E & TC )
SEVEN SISTERS LOB - BOARD 1 ROUTE INTERLOCKING
VL1_1U_RIU relay Seven Sisters HS45611/395A VL1_1U_RUM & !VL1_2U_RIU
VL1_2U_RIU relay Seven Sisters HS45611/395A VL1_2U_RUM & !VL1_1U_RIU & !VL21U_RIU & !VL22_2U_RIU
VL2U_RIU relay Seven Sisters HS45611/395A VL2U_RUM & !VL6_1U_RIU
VL4U_RIU relay Seven Sisters HS45611/395A VL4U_RUM & !VL6_1U_RIU & ( !VL5U_RIU | VL12{N} )
VL5U_RIU relay Seven Sisters HS45611/395A VL5U_RUM & !VL21U_RIU & !VL22_2U_RIU & ( !VL4U_RIU | VL12{N} )
VL6_1U_RIU relay Seven Sisters HS45611/395A VL6_1U_RUM & !VL2U_RIU & !VL4U_RIU & !VL6_2U_RIU & !VL6_3U_RIU & !VL21U_RIU & !VL22_2U_RIU & ( !VL4U_RIU | VL12{N} )
VL6_2U_RIU relay Seven Sisters HS45611/395A VL6_2U_RUM & !VL6_1U_RIU & !VL6_3U_RIU & !VL8U_RIU & !VL20U_RIU & !VL21U_RIU & !VL22_2U_RIU
VL6_3U_RIU relay Seven Sisters HS45611/395A VL6_3U_RUM & !VL6_1U_RIU & !VL6_2U_RIU & !VL8U_RIU & !VL20U_RIU & !VL21U_RIU & !VL22_1U_RIU & !VL22_2U_RIU & !VL23U_RIU & VL17{N}
VL7U_RIU relay Seven Sisters HS45611/395A VL7U_RUM & !VL20U_RIU
VL8U_RIU relay Seven Sisters HS45611/395A VL8U_RUM & !VL6_2U_RIU & !VL6_3U_RIU & !VL18U_RIU & !VL19U_RIU & !VL20U_RIU & !VL22_1U_RIU & !VL22_2U_RIU & !VL24U_RIU
VL18U_RIU relay Seven Sisters HS45611/395A VL18U_RUM & !VL8U_RIU
VL19U_RIU relay Seven Sisters HS45611/395A VL19U_RUM & !VL8U_RIU & !VL24U_RIU
VL20U_RIU relay Seven Sisters HS45611/395A VL20U_RUM & !VL6_1U_RIU & !VL6_2U_RIU & !VL7U_RIU & !VL8U_RIU & !VL22_1U_RIU & !VL22_2U_RIU & !VL24U_RIU
VL21U_RIU relay Seven Sisters HS45611/395A VL21U_RUM & !VL1_2U_RIU & !VL5U_RIU & !VL6_1U_RIU & !VL6_2U_RIU & !VL6_3U_RIU
VL22_1U_RIU relay Seven Sisters HS45611/395A VL22_1U_RUM & !VL6_3U_RIU & !VL8U_RIU & !VL20U_RIU & !VL22_2U_RIU & !VL24U_RIU & VL13{N}
VL22_2U_RIU relay Seven Sisters HS45611/395A VL22_2U_RUM & !VL1_2U_RIU & !VL5U_RIU & !VL6_1U_RIU & !VL6_2U_RIU & !VL6_3U_RIU & !VL8U_RIU & !VL20U_RIU & !VL22_1U_RIU & VL17{N}
VL23U_RIU relay Seven Sisters HS45611/395A VL23U_RUM & !VL6_3U_RIU
VL24U_RIU relay Seven Sisters HS45611/395A VL24U_RUM & !VL8U & !VL19U_RIU & !VL20U_RIU &!VL22_1U_RIU
SEVEN SISTERS LOB - BOARD 2 SIGNAL LEVER OPERATIONS
VL1{NPUFF} attr Seven Sisters Should automate the line creation for sigs? And second puff? HS45611/396C !VL1{RPUFF} & ( VL1{RE} | VL1_L )
VL1{RPUFF} attr Seven Sisters HS45611/396C ( ( VL1_1U_RIU & VL10{N} ) | ( VL1_2U_RIU & VL10{R} ) )
VL4{NPUFF} attr Seven Sisters HS45611/396C !VL4{RPUFF} & ( VL4{RE} | VL4_L )
VL4{RPUFF} attr Seven Sisters HS45611/396C VL4U_RIU & VL12{N}
VL5{NPUFF} attr Seven Sisters HS45611/396C !VL5{RPUFF} & ( VL5{RE} | VL5_L )
VL5{RPUFF} attr Seven Sisters VL5U_RIU & VL21{N} HS45611/396C VL5U_RIU & VL21{N} Don't understand ----> VL5U_RIU & VL21{N} & ( VL12{N} | VL12{NPUFF} ) & ( VL13{N} | VL13{NPUFF} ) & ( VL12{R} | VL12{RPUFF} ) & ( VL13{R} | VL13{RPUFF} )
VL6{NPUFF} attr Seven Sisters HS45611/396C !VL6{RPUFF} & ( VL6{RE} | VL6_L )
VL6{RPUFF} attr Seven Sisters HS45611/396C ( ( VL6_1U_RIU & VL12{R} & VL13{N} ) | ( VL6_2U_RIU & VL12{N} & VL13{N} & VL14{N} & VL15{R} ) | ( VL6_3U_RIU & VL12{N} & VL13{R} & VL16{R} & VL17{N} & VL23{N} ) ) & VL21{N}
VL7{NPUFF} attr Seven Sisters HS45611/396C !VL7{RPUFF} & ( VL7{RE} | VL7_L )
VL7{RPUFF} attr Seven Sisters HS45611/396C VL7U_RIU & VL20{N}
VL8{NPUFF} attr Seven Sisters HS45611/396C !VL8{RPUFF} & ( VL8{RE} | VL8_L )
VL8{RPUFF} attr Seven Sisters HS45611/396C VL8U_RIU & VL14{R} & VL15{R} & VL18{N} & VL19{N} & VL20{N}
VL18{NPUFF} attr Seven Sisters HS45611/396C !VL18{RPUFF} & ( VL18{RE} | VL18_L )
VL18{RPUFF} attr Seven Sisters HS45611/396C VL18U_RIU & VL8{N}
VL19{NPUFF} attr Seven Sisters HS45611/396C !VL19{RPUFF} & ( VL19{RE} | VL19_L )
VL19{RPUFF} attr Seven Sisters HS45611/396C VL19U_RIU & VL8{N} & VL17{R}
VL20{NPUFF} attr Seven Sisters HS45611/396C !VL20{RPUFF} & ( VL20{RE} | VL20_L )
VL20{RPUFF} attr Seven Sisters HS45611/396C VL20U_RIU & VL7{N} & VL8{N} & VL14{R} & VL15{R}
VL22{NPUFF} attr Seven Sisters HS45611/396C !VL22{RPUFF} & ( VL22{RE} | VL22_L )
VL22{RPUFF} attr Seven Sisters HS45611/396C ( ( VL22_1U_RIU & VL13{N} & VL16{R} & VL17{R} ) | ( VL22_2U_RIU & VL13{R} & VL16{R} & VL17{N} & VL21{R} ) )
VL23{NPUFF} attr Seven Sisters HS45611/396C !VL23{RPUFF} & ( VL23{RE} | VL23_L )
VL23{RPUFF} attr Seven Sisters HS45611/396C VL23U_RIU & ( VL6{N} | VL13{N} )
VL24{NPUFF} attr Seven Sisters HS45611/396C !VL24{RPUFF} & ( VL24{RE} | VL24_L )
VL24{RPUFF} attr Seven Sisters HS45611/396C VL24U_RIU & VL17{N}
VL2{NPUFF} attr Seven Sisters HS45611/396C !VL2{RPUFF} & ( VL2{RE} | VL2_L )
VL2{RPUFF} attr Seven Sisters HS45611/396C VL2U_RIU & VL12{N}
VL21{NPUFF} attr Seven Sisters HS45611/396C !VL21{RPUFF} & ( VL21{RE} | VL21_L )
VL21{RPUFF} attr Seven Sisters HS45611/396C VL21U_RIU & VL5{N} & VL6{N} & VL11{N}
VL9{NPUFF} attr Seven Sisters HS45611/396C !VL9_JCSR
VL9{RPUFF} attr Seven Sisters HS45611/396C ( VL9_JCSR & VL9_L ) | VL9REL_JR
VL9REL_JR relay Seven Sisters 4 HS45611/408B VL9{NA} & VL9_JCSR
SEVEN SISTERS LOB - BOARD 3 POINT LEVER OPERATIONS
VL10_N_DELAY relay Seven Sisters 2 HS45611/397F !VL10{N}
VL10_R_DELAY relay Seven Sisters 2 HS45611/397F !VL10{R}
VL12_N_DELAY relay Seven Sisters 2 HS45611/397F !VL12{N}
VL12_R_DELAY relay Seven Sisters 2 HS45611/397F !VL12{R}
VL10{NPUFF} attr Seven Sisters HS45611/397F ( !VL1_2U_RIU & VL1{N} & VL10_N_DELAY & VL10_L ) | ( VL10{N} & !VL1_2U_RIU )
VL10{RPUFF} attr Seven Sisters HS45611/397F VL1_2U_RIU & VL11{R} & VL10_R_DELAY & VL10_L
VL11{NPUFF} attr Seven Sisters HS45611/397F !VL1_2U_RIU & VL10{N} & VL11_L
VL11{RPUFF} attr Seven Sisters HS45611/397F VL1_2U_RIU & VL21{N} & VL11_L
VL12{NPUFF} attr Seven Sisters HS45611/397F ( !VL6_1U_RIU & VL5{N} & VL6{N} & VL12_N_DELAY & VL12_L ) | ( !VL6_1U_RIU & VL12{N} ) Don’t understand ( VL5{RPUFF} & !VL6_1U_RIU & VL5{N} & VL6{N} & VL12_N_DELAY & VL12_L ) | ( !VL6_1U_RIU & VL12{N} )
VL12{RPUFF} attr Seven Sisters HS45611/397F VL6_1U_RIU & ( VL15{N} | VL14{R} ) & VL2{N} & VL4{N} & VL5{N} & VL13{N} & VL12_R_DELAY & VL12_L
VL13{NPUFF} attr Seven Sisters HS45611/397F ( !VL6_3U_RIU & !VL22_2U_RIU & VL5{N} &VL6{N} & VL16{N} & VL22{N} & VL13_L ) | ( VL13{N} & !VL6_3U_RIU & !VL22_2U_RIU ) Don't understand ( VL5{RPUFF} & !VL6_3U_RIU & !VL22_2U_RIU & VL5{N} &VL6{N} & VL16{N} & VL22{N} & VL13_L ) | ( VL13{N} & !VL6_3U_RIU & !VL22_2U_RIU )
VL13{RPUFF} attr Seven Sisters HS45611/397F ( VL6_3U_RIU | VL22_2U_RIU ) & VL5{N} & VL12{N} & VL13_L
VL14{NPUFF} attr Seven Sisters HS45611/397F !VL8U_RIU & !VL20U_RIU & VL8{N} & VL20{N} & VL14_L
VL14{RPUFF} attr Seven Sisters HS45611/397F ( VL8U_RIU | VL20U_RIU ) & VL16{N} & VL17{R} & ( VL6{N} | VL12{R} | VL13{R} ) & VL14_L
VL15{NPUFF} attr Seven Sisters HS45611/397F !VL6_2U_RIU & !VL8U_RIU & !VL20U_RIU & VL8{N} & VL20{N} & ( VL6{N} | VL12{R} | VL13{R} ) & VL15_L
VL15{RPUFF} attr Seven Sisters HS45611/397F ( VL12{N} | VL14{R} ) & ( VL6_2U_RIU | VL8U_RIU | VL20U_RIU ) & ( VL16{N} | VL13{N} ) & VL15_L
VL16{NPUFF} attr Seven Sisters HS45611/397F !VL6_3U_RIU & !VL22_1U_RIU & !VL22_2U_RIU &VL22{N} & ( VL6{N} | VL13{N} ) & VL16_L
VL16{RPUFF} attr Seven Sisters HS45611/397F ( VL13{R} | VL17{R} ) & ( VL6_3U_RIU | VL22_1U_RIU | VL22_2U_RIU ) & VL14{N} & ( VL15{N} | VL13{N} ) & VL16_L
VL17{NPUFF} attr Seven Sisters HS45611/397F ( !VL8U_RIU & !VL19U_RIU & !VL20U_RIU & !VL22_1U_RIU & ( VL22{N} | VL13{R} ) & VL14{N} & VL16{N} & VL17_L & VL19_L ) | ( !VL17_L & VL17{NA} )
VL17{RPUFF} attr Seven Sisters HS45611/397F ( ( VL8U_RIU | VL19U_RIU | VL20U_RIU | VL22_1U_RIU ) & VL17_L & VL24{N} & ( VL6{N} | VL13{N} ) & ( VL22{N} | VL13{N} ) ) | ( !VL17_L & VL17{RE} )
VLS3{201_1} - VLS3{221}
VLS3{201_1_store} attr HS45611/459L VLS3{571} & !( TH & TJ ) & VL18G & ( VLS3{612} | VLS3{613} | VLS3{614} ) & VL24{633}
VLS3{201_1_canc} attr HS45611/459L VLS3{113} & VLS3{611} & VLS3{221} & VLS3{332}
VLS3{221} attr
VLS3{201_2} - VLS3{222}
VLS3{201_2_store} attr HS45611/459L ( VL33G17 & VL18G & !( TH & TJ ) & VL21{633} & VLS3{160} & !VLS3{571} ) | ( !VLS3{571} & VL22{633} & VL18G & !( TH & TJ ) & VL33G17 & !VLS3{161} )
VLS3{201_2_canc} attr HS45611/459L VLS3{113} & VLS{612} & VLS3{222} & VLS3{332}
VL33G17 relay HS45611/459L VLS3{611} & VLS3{612} & VLS3{614}
VLS3{220} attr
VLS3{202} - VLS3{220}
VLS3{202_store} attr HS45611/459L ( VL18G & !( TH & TJ ) & VLS3{161} & VL22{633} & !VLS3{571} ) | ( !VLS3{571} & VL20{633} & !( TH & TJ ) & VL33D16 & !VLS3{160} )
VLS3{202_canc} attr HS45611/459L VLS3{332} & VLS3{113} & VLS3{613} & VLS3{220}
VL333D16 relay HS45611/459L VLS3{611} & VLS3{612} & VLS3{614}
VLS3{220} attr
VLS3{203} - VLS3{225}
VLS3{203_store] attr CHECK HS45611/459L !VLS3{571} & !TC & VL18G & ( VLS3{611} | VLS3{612} | VLS3{613} ) & VL24{633) 
VLS3{203_canc} attr HS45611/459L VLS3{113} & VLS3{614} & VLS3{225} & ( VLSB{475} | ( !VLSB{475} & !VL53{377} ) ) & VLS3{225}
VLS3{225} attr
VL10{NWKR} attr col45 VL_EXTRA VL10{N}
VL10{RWKR} attr col46 VL_EXTRA VL10{R}
VL11{NWKR} attr col45 VL_EXTRA VL11{N}
VL11{RWKR} attr col46 VL_EXTRA VL11{R}
VL12{NWKR} attr col45 VL_EXTRA VL12{N}
VL12{RWKR} attr col46 VL_EXTRA VL12{R}
VL13{NWKR} attr col45 VL_EXTRA VL13{N}
VL13{RWKR} attr col46 VL_EXTRA VL13{R}
VL14{NWKR} attr col45 VL_EXTRA VL14{N}
VL14{RWKR} attr col46 VL_EXTRA VL14{R}
VL15{NWKR} attr col45 VL_EXTRA VL15{N}
VL15{RWKR} attr col46 VL_EXTRA VL15{R}
VL16{NWKR} attr col45 VL_EXTRA VL16{N}
VL16{RWKR} attr col46 VL_EXTRA VL16{R}
VL17{NWKR} attr col45 VL_EXTRA VL17{N}
VL17{RWKR} attr col46 VL_EXTRA VL17{R}
VL4U_INV_OR_12_NWKR relay col59 VL_LOB1 !VL4U_RIU | VL12{NWKR}
VL5U_INV_OR_12_NWKR relay col61 VL_LOB1 !VL5U_RIU | VL12{NWKR}
VL12{NINT} attr col71 VL_LOB2 !VL12{NPUFF}
VL12{RINT} attr col72 VL_LOB2 !VL12{RPUFF}
VL13{NINT} attr col73 VL_LOB2 !VL13{NPUFF}
VL13{RINT} attr col74 VL_LOB2 !VL13{RPUFF}
VL5{RINT} attr col4 VL_LOB3 !VL5{RPUFF}
VL12_NWKR_OR_VL12_NINT relay col49 VL_LOB2 VL12{NWKR} | VL12{NINT}
VL13_NWKR_OR_VL13_NINT relay col50 VL_LOB2 VL13{NWKR} | VL13{NINT}
VL6_N_OR_VL13_NWKR relay col51 VL_LOB2 VL6{N} | VL13{NWKR}
VL12_NWKR_OR_VL14_RWKR relay and LOB3/col7 col52 VL_LOB2 VL12{NWKR} | VL14{RWKR}
VL13_RWKR_OR_VL17_RWKR relay and LOB3/col10 col53 VL_LOB2 VL13{RWKR} | VL17{RWKR}
VL6_3U_OR_VL22_2U_RIU relay col64 VL_LOB2 VL6_3U_RIU | VL22_2U_RIU
VL8U_OR_VL20U_RIU relay col65 VL_LOB2 VL8U_RIU | VL20U_RIU
VL6_2U_OR_VL8U_OR_VL20U_RIU relay col66 VL_LOB2 VL6_2U_RIU | VL8U_OR_VL20U_RIU
VL6_3U_OR_VL22_1U_OR_VL22_2U_RIU relay col67 VL_LOB2 VL6_3U_RIU | VL22_1U_RIU | VL22_2U_RIU
VL8U_OR_VL19U_OR_VL20U_OR_VL22_1U_RIU relay col68 VL_LOB2 VL8U_OR_VL20U_RIU | VL19U_RIU | VL22_1U_RIU
VL12RWKR_OR_VL12RINT relay col69 VL_LOB2 VL12{RWKR} | VL12{RINT}
VL13RWKR_OR_VL13RINT relay col70 VL_LOB2 VL13{RWKR} | VL13{RINT}
VL6_1U_RPUFF relay row5 VL_LOB2 VL6_1U_RIU & VL12{R} & VL13{N}
VL6_2U_RPUFF relay row6 VL_LOB2 VL6_2U_RIU & VL12{N} & VL13{N} & VL14{N} & VL15{R}
VL6_3U_RPUFF relay row7 VL_LOB2 VL6_3U_RIU & VL12{N} & VL13{R} & VL16{R} & VL17{N} & VL23{N}
VL1_1U_RPUFF relay row1 VL_LOB2 VL1_1U_RIU & VL10{N}
VL1_2U_RPUFF relay row21 VL_LOB2 VL1_2U_RIU & VL10{R}
VL22_1U_RPUFF relay row13 VL_LOB2 VL22_1U_RIU & VL13{N} & VL16{R} & VL17{R}
VL22_2U_RPUFF relay row14 VL_LOB2 VL22_2U_RIU & VL13{R} & VL16{R} & VL17{N} & VL21{R}
VL9_L_AND_JCSR relay row21 VL_LOB2 VL9_L & VL9_JCSR
VL15_NWKR_OR_VL14_RWKR relay col8 VL_LOB3 VL15{NWKR} | VL14{RWKR}
VL22N_OR_VL13{RWKR} relay col30 VL_LOB3 VL22{N} | VL13{RWKR}
VL6_N_OR_VL12_RWKR_OR_VL13_RWKR relay col61 VL_LOB3 VL6{N} | VL12{RWKR} | VL13{RWKR}
VL16_NWKR_OR_VL13_NWKR relay col63 VL_LOB3 VL16{NWKR} | VL13{NWKR}
VL15_NWKR_OR_VL13_NWKR relay col64 VL_LOB3 VL15{NWKR} | VL13{NWKR}
VL6_N_OR_VL13_NWKR relay col65 VL_LOB3 VL6{N} | VL13{NWKR}
VL22_N_OR_VL13_NWKR relay col66 VL_LOB3 VL22{N} | VL13{NWKR}
VL10_N_DELAY defined elsewhere col67 VL_LOB3
VL10_R_DELAY defined elsewhere col68 VL_LOB3
VL12_N_DELAY defined elsewhere col69 VL_LOB3
VL12_R_DELAY defined elsewhere col70 VL_LOB3
VL10_NPUFFa relay row1 VL_LOB3 !VL1_2U_RIU & VL1{N} & VL10_N_DELAY & VL10_L
VL10_NPUFFb relay row19 VL_LOB3 VL10{N} & !VL1_2U_RIU
VL12_NPUFFa relay row5 VL_LOB3 !VL6_1U_RIU & VL5{N} & VL6{N} & VL12_N_DELAY & VL12_L
VL12_NPUFFb relay row20 VL_LOB3 !VL6_1U_RIU & VL12{N}
VL13_NPUFFa relay row7 VL_LOB3 !VL6_3U_RIU & !VL22_2U_RIU & VL5{N} &VL6{N} & VL16{N} & VL22{N} & VL13_L
VL13_NPUFFb relay row21 VL_LOB3 VL13{N} & !VL6_3U_RIU & !VL22_2U_RIU
VL17_NPUFFa relay row15 VL_LOB3 !VL8U_RIU & !VL19U_RIU & !VL20U_RIU & !VL22_1U_RIU & ( VL22{N} | VL13{R} ) & VL14{N} & VL16{N} & VL17_L & VL19_L
VL17_NPUFFb relay row16 VL_LOB3 !VL17_L & VL17{NA}
VL17_RPUFFa relay row17 VL_LOB3 ( VL8U_RIU | VL19U_RIU | VL20U_RIU | VL22_1U_RIU ) & VL17_L & VL24{N} & ( VL6{N} | VL13{N} ) & ( VL22{N} | VL13{N} )
VL17_RPUFFb relay row18 VL_LOB3 !VL17_L & VL17{RE}
T233_SPECIAL_LEFT_VN relay !SL & VNS1{regTIME} eq "12:01:30" & SL{tn} eq "233"
T233_SPECIAL_ENROUTE relay ( REG_AUTO_233 & T233_SPECIAL_LEFT_VN ) | ( T233_SPECIAL_ENROUTE & REG_AUTO_233 & !VL8U_SPECIAL_CALL )
VL23U_SPECIAL_CALL relay T233_SPECIAL_ENROUTE & !464A & 464B & SP & SQ & ST & SU & SV & TC & TE
VL22_1U_SPECIAL_CALL relay T233_SPECIAL_ENROUTE & VL23G
VL19U_SPECIAL_CALL relay T233_SPECIAL_ENROUTE & VL22AG
VL8U_SPECIAL_CALL relay T233_SPECIAL_ENROUTE & VL19G